Fast Gradient Echo Sequences Including Balanced SSFP

نویسنده

  • Brian Hargreaves
چکیده

Many common magnetic resonance imaging sequences are classified either as spin echo or gradient echo techniques. Generally, a gradient echo occurs when spins are coherent regardless of their position within the sample. This occurs whenever the net gradient area since a previous echo is zero. In a spin echo, spins are coherent regardless of their resonance frequency [1]. Here we will focus on gradient echoes in more detail, including how they evolve, and the so-called gradient-echo pulse sequences. These include gradient spoiled sequences, RFspoiled sequences and balanced steady-state free precession (SSFP) sequences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spoiled & Balanced Gradient Echo Methods

Imaging with spoiled, balanced or nonbalanced gradient echo (GRE) refers to a class of fast imaging sequences that use a dynamic equilibrium or steady state signal for imaging. As originally introduced in 1958 by Carr (1) for NMR spectroscopy, a dynamic equilibrium or steadystate can be established by a train of radio-frequency (RF) excitation pulses interleaved by periods of ‘free precession’,...

متن کامل

Flow compensation in non-balanced SSFP

Introduction. Non-balanced steady-state free precession sequences (SSFP-FID and SSFP-echo) are gradient-spoiled pulse sequences that provide high signal even in presence of long T1 values, because the transverse magnetization is not completely incoherent by means of radiofrequency spoiling. Contrary to balanced SSFP sequences they do not suffer from off-resonance banding artifacts, making them ...

متن کامل

Can left ventricular endocardial surface roughness be measured by fractal dimension on fast gradient echo sequences?

Background Left ventricular (LV) fractal dimension (FD) on cardiac magnetic resonance (CMR) balanced steady-state free precession (SSFP) cines has already proven to be useful in making a diagnosis of non-compaction cardiomyopathy. Normal FD values for SSFP cines have been established (Captur 2015). Fast gradient echo (fGRE) sequences have different contrast between blood pool and myocardium, wh...

متن کامل

SNR using balanced steady-state free precession (b-SSFP)

A brief overview of the signal-to-noise ratio in MR imaging; including the sources of signal and noise and their respective parameters for optimization. In particular, the balanced SSFP sequence is presented as an example of a special type of gradient-echo (GE) sequence where the dephasing due to readout gradient is exactly zero. Thus b-SSFP yields a very high SNR, in some applications, by cont...

متن کامل

Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging.

PURPOSE To retrospectively evaluate the conspicuity of liver lesions in a fluoroscopic spoiled gradient echo (GRE) and a balanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) sequence. MATERIALS AND METHODS In all, 103 patients with hepatocellular carcinomas (HCC) (41) or liver metastases (67) were treated using MR-guided radiofrequency ablation in a wide-bore 1.5 T sc...

متن کامل