FEG-EPMA of Solid State Redox Sensors – the Effect of Secondary Fluorescence on Analytical Precision

نویسندگان

  • Jon Wade
  • Ben Buse
  • Stuart Kearns
چکیده

High-pressure oxygen fugacity (‘redox’) sensors are widely used to make estimates of the effective concentration of oxygen in experimental petrology. They typically rely on iron either diffusing into a nominally iron free mineral (e.g. iron into magnesiowüstite [1]) or iron alloying with a noble metal[2, 3]. In both cases the iron content of the sensor material should reflect the prevailing oxygen fugacity of the experiment, assuming all the phases are in local chemical equilibrium. The composition of the sensor is typically controlled by diffusion of iron into a crystalline (e.g. MgO) or solid metallic material, hence for accurate estimation of the experimental redox conditions, analysis of the sensor’s iron content is made as close as possible to the sensor/experiment boundary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of mesoporous silica SBA-15 with different organic molecules to gain chemical sensors: a review

The recognition of the biologically and environmentally important ions is of great interest in the field of chemical sensors in recent years. The fluorescent sensors as a powerful optical analytical technique for the detection of low level of various analytes such as anions and metal cations have been progressively developed due to the simplicity, cost effective, and selectivity for monitoring ...

متن کامل

Preparation of Nickel Nanoparticles by Intramolecular Reaction of Nickel(II) Hydrazine Complex in the Solid State at Room Temperature

Ni6(N2H4)6(SO4)4(OH)2(H2O)8](SO4)(H2O)10 complex was prepared according to literature report. The reaction between aforementioned complex via sodium alkoxides as a reactants, were carried out in the solid state. The [Ni6(N2H4)6(SO4)4(OH)2(H2O)8](SO4)(H2O)10 undergoes an intramolecular two electrons oxidation-reduction reaction at room temperature and metallic nickel nanoparticles (Ni1-Ni5) was ...

متن کامل

Electron Probe Microanalysis (EPMA)

An electron microprobe is an electron microscope designed for the non-destructive x-ray microanalysis and imaging of solid materials. It is essentially a hybrid instrument combining the capabilities of both the scanning electron microscope (SEM) and an x-ray fluorescence spectrometer (XRF), with the added features of fine-spot focusing (~ 1 micrometer), optical microscope imaging, and precision...

متن کامل

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

Effect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement

Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014