A comparison of flow rates and warming capabilities of the Level 1 and Rapid Infusion System with various-size intravenous catheters.

نویسندگان

  • Sandra L Barcelona
  • Fatima Vilich
  • Charles J Coté
چکیده

UNLABELLED Cases involving massive blood transfusion may require the use of specialized blood warmers, such as the Level 1 (L-1) (Level 1 Technologies, Inc., Rockland, MA) or the Rapid Infusion System (RIS) (Haemonetics Corp., Braintree, MA). In this in vitro study, we compared the infusion and warming capabilities of the L-1 (model 1000) versus the RIS using pediatric- and adult-sized IV catheters. The time to infuse 2 L of lactated Ringer's solution and the end temperature after infusion through 20-, 18-, 16-, and 14-gauge catheters, and 4-, 5-, 6-, 7-, and 8.5-French catheters using both the L-1 and RIS were measured. The flow rates of both systems were similar for 18- and 20-gauge catheters; however, the flow rates with the RIS were progressively faster than the L-1 as catheter size increased to >18 gauge. The heating capabilities of the RIS were superior to the L-1 for all catheters >or=16 gauge. We conclude that the RIS was superior to the L-1 for both flow rates and warming capacity for all IV catheters >18 gauge, i.e., those used for cases with massive blood loss. The RIS provided no advantage (with regard to heating and flow) when used with typical pediatric-sized catheters. IMPLICATIONS The rapid infusion system is superior to the Level 1 for warming and flow of crystalloid for IV catheters >18 gauge in vitro. The rapid infusion system provides no advantage with catheters typically used in small children (<or=18 gauge). Safety and cost are additional factors to be considered when choosing one system over the other.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The survey of Rrespiratory Rate, SPO2, nausea and vomiting in the use of three methods (warmed intravenous fluids, combined warming and pethidine) in patients with shivering

Introduction: Shivering after anaesthesia and surgery is a common complication. Different methods are used for control of shivering in the recovery room. The opioids such as pethidine are very common in shivering control. Pethidine can be induced apnea, respiratory depression and nausea &vomiting. The respiratory rate and spo2 can lead to more rapid diagnosis and treatment of serious hypoxemia ...

متن کامل

Comparison of the Effects of Intralipid 10% and 20% on Peripheral Catheter Ablation in a Pediatric Intensive Care Unit

Background: Energy deficit is a common and serious problem in pediatric intensive care units. Parenteral nutrition, either alone or in combination with enteral nutrition, can improve nutrient delivery in critically ill patients by preventing or correcting the energy deficit and improving the outcomes. Intralipid 10% and 20% are lipid emulsions, widely used in parenteral nutrition. Despite sever...

متن کامل

Comparative flow rates of thin-walled and conventional-walled intravenous catheters.

The rapid administration of intravenous fluids is often a major consideration during the course of an anesthetic. This in vitro study was undertaken to compare fluid flow rates through 18- and 20-gauge intravenous catheters in both thin-wall and conventional-wall designs. All brands and types of catheters of similar sizes have the same outer diameter; however, the inner diameter may vary accord...

متن کامل

Complications of Peripheral Intravenous Catheters During 72 Hours After Insertion

Introduction: Peripheral Intravenous catheterization is the most commonly used invasive treatment method in patients admitted to the hospitals, but it has some complications. The indwell time of catheter is one of the factors associated with the occurrence of complications, especially phlebitis. In spite of the instructions for replacing the catheters after 72 hours, sometimes the complications...

متن کامل

Induction of general anaesthesia with intraosseous injection of thiopental in rabbits

The technique of intraosseous (IO) infusion has been reemerged as an alternative route of intravascular access for the delivery of fluids and some medications. Complications of IO infusion occur rarely and include fractures and osteomyelitis after long-term use of IO access. The purpose of this study was to compare the efficiency of induction of anaesthesia by a standard intravenous route and a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 97 2  شماره 

صفحات  -

تاریخ انتشار 2003