Ulna Rotation Osteotomy in Complete Dislocation of the Distal Radioulnar Joint.

نویسندگان

  • Markus Gabl
  • Rohit Arora
  • Eva Maria Gassner
  • Gernot Schmidle
چکیده

Background Complete dislocation of the distal radioulnar joint (DRUJ) is a rare injury. Dislocation can present as uni- or multidirectional, acute or chronic, reducible or irreducible. It can occur due to isolated loss of ligamentous restraints or more frequent in Galeazzi - or Essex-Lopresti-type fractures. Case Description A 28-year-old man sustained a distal radius fracture and presented after conservative treatment with blocked supination. Examination revealed a malunion of the distal radius in combination with an irreducible dorsal dislocation of the DRUJ. Corrective osteotomy of the distal radius was performed, the DRUJ was reduced, and the ulnar avulsed triangular fibrocartilage complex (TFCC) refixed with transosseous sutures. Redislocation occurred 8 weeks later. Revision surgery showed a palmar dislocated TFC fixed in a palmar scar formation along the distal interosseous membrane (DIOM). The scar was released and a rotation osteotomy of the distal ulna was performed. At follow-up, the patient was pain-free, had good range of motion, and returned to work and sport activities. Literature Review For reconstruction of chronic complete dislocations of the DRUJ, ligament plasty procedures are described. In case of additional cartilage damage, salvage procedures are recommended. Clinical Relevance We report a procedure in which the rotation of the distal ulna is corrected to restore DRUJ congruity in chronic dislocations. The rotation osteotomy described is useful in gross ligamentous instability following loss of constraint by the TFCC and the DIOM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new external fixation method in Colles’ fracture associated with the distal radioulnar joint dislocation in elderly patients

Background: Isolated distal radioulnar joint (DRUJ) dislocation is uncommon. It always associated with the radius and ulna fracture (distal radius fracture, Galeazzi, Monteggia fracture or the Essex-Lopresti forearm fracture). Many of DRUJ dislocation associated with distal radius fracture, especially Colles’ fracture. Volar locking plate (VLP) must be used to fix the distal fragments and the c...

متن کامل

Rotational osteotomies for congenital radioulnar synostosis.

In five children, six forearms with a fixed pronation deformity secondary to congenital radioulnar synostosis were treated by a derotation osteotomy of the distal radius and the midshaft of the ulna. There were three boys and two girls with a mean age of 4.9 years (3.5 to 8.25) who were followed up for a mean of 29 months (18 to 43). The position of the forearm was improved from a mean pronatio...

متن کامل

The Scheker distal radioulnar joint arthroplasty to unravel a virtually unsolvable problem.

Failure of the distal radioulnar joint leads to significant dysfunction of the upper limb. Numerous surgical procedures have been suggested to address this problem. In degenerative arthritis, joint instability and ulnar stump dislocation after salvage procedures such as Darrach distal resection or Sauvé-Kapandji distal fusion, an ideal solution may not be available. The ultimate option to resto...

متن کامل

Results of Sauve-kapandji procedure.

INTRODUCTION Sauve-Kapandji procedure is used to treat distal radioulnar joint disorder. MATERIALS AND METHOD Sixteen patients with distal radioulnar joint (DRUJ) disease treated with Sauve-Kapandji procedure between 1996 and 1998 were available for review at an average follow up period of 32.8 months,ranging from 24 to 48 months. The patients were young and the average age at the time of pro...

متن کامل

The dorsopalmar stability of the distal radioulnar joint.

Sixteen fresh-frozen adult human cadaveric upper extremities were used in a biomechanical analysis of distal radioulnar joint (DRUJ) stability. The relative contribution to stability of the DRUJ by the surrounding anatomic structures presumed to stabilize the joint was analyzed with respect to forearm rotation and wrist flexion and extension using a purpose-built 4-axis materials testing machin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of wrist surgery

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2017