Coronary stent immobilization during angioplasty by transcoronary ventricular pacing via a guidewire.

نویسندگان

  • Garikoitz Lasa
  • Mariano Larman
  • Koldo Gaviria
  • Juan Carlos Sanmartín
  • Mario Sádaba
  • José Ramón Rumoroso
چکیده

INTRODUCTION AND OBJECTIVES In some patients, cardiac contractions cause the coronary artery segment adjacent to a stent to move in such a way that accurate stent positioning is difficult. A number of techniques have been described for immobilizing the stent at the target site by inducing periods of either asystole or tachycardia. This study shows how pulsatile motion can be controlled by means of rapid ventricular pacing via an angioplasty guidewire. METHODS The study involved 27 consecutive patients in whom excessive stent movement during angioplasty complicated accurate stent implantation. In these selected patients, myocardial tachycardia was induced by transcoronary ventricular pacing via an angioplasty guidewire with the aim of reducing the pulsatile motion of the stent. RESULTS At baseline, the median displacement was 4.08 mm (interquartile range 2.75 mm). During pacing at 100 and 150 beats per minute, the median displacement was 1.39 mm and 0.54 mm, respectively (interquartile range 1.66 mm and 0.54 mm, respectively). Transcoronary myocardial pacing was effective in 96% of cases. No complications associated with pacing were reported. CONCLUSIONS Transcoronary ventricular pacing via an angioplasty guidewire was an effective and safe method for achieving stent immobilization in cases where there was excessive pulsatile motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left main coronary stent positioning using rapid transcoronary pacing.

Temporary transcoronary unipolar pacing is a validated simple, effective, and safe alternative to temporary transvenous pacing of the right ventricle for the treatment of relevant bradyarrhythmias complicating percutaneous coronary intervention. We describe the use of rapid transcoronary pacing to aid precise placement of a stent in the left main coronary artery bifurcation.

متن کامل

Surgical removal of guidewire entrapped within stent struts during percutaneous coronary angioplasty.

There has been a growing trend toward percutaneous coronary angioplasty for complex coronary artery lesions. Stent or guidewire break off or trapping within the coronary artery lumen is a rare complication, but it may have fatal consequences. In such cases, the entrapped device may be removed by either percutaneous route or surgical exploration. Here, we report a patient with guidewire entrapme...

متن کامل

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Rescue-stenting of an occluded lateral coronary sinus branch for recanalization after dissection during cardiac resynchronization device implantation.

Cardiac resynchronization therapy (CRT) using left- (LV) or biventricular pacing is widely applied in selected heart failure patients. However, transvenous LV-lead placement into coronary sinus (CS) branches can be challenging. A 77-year-old female patient with New York Heart Association class III symptoms due to dilated cardiomyopathy [LV ejection fraction (LVEF): 10%, QRS-duration: 150 ms], d...

متن کامل

Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve.

BACKGROUND There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. METHODS AND RESULTS A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 62 3  شماره 

صفحات  -

تاریخ انتشار 2009