Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli.

نویسندگان

  • Karin Y Gfeller
  • Natalia Nugaeva
  • Martin Hegner
چکیده

A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated by common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The sensor is able to detect active growth of Escherichia coli cells within 1 h which is significantly faster than any conventional plating method which requires at least 24 h. The growth of E. coli was confirmed by scanning electron microscopy. This new sensing method for the detection of active bacterial growth allows future applications in, e.g., rapid antibiotic susceptibility testing by adding antibiotics to the nutritive layer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid biosensor for detection of antibiotic-selective growth of Escherichia coli.

A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated in common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The calculated mass sensitivity according to the mechanical properties of the cantilever sensor is approximately 50 pg/Hz; t...

متن کامل

Investigation of immunosensor modification with reduced Graphene Oxide with Au Nanoparticles on glassy carbon electrode in Label-free for Escherichia coli detection

Escherichia coli is an indicator in the quality control of pharmaceutical and other samples. Reduced graphene oxide (rGO) as a kind of carbon compositions was immobilized on glassy carbon electrode (GCE). Chronoamperometric and reduction methods were used for Au NPs decoration and it completed with polyclonal E. coli antibody and 0.5 W/V% Bovine Serum Albumin solution. Morphology and structure ...

متن کامل

Point-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor

Objective(s): Access to safe drinking and irrigation water has always been one of the major human concerns worldwide. Thus, rapid, sensitive, and inexpensive approaches for pathogenic bacteria detection, such as Escherichia coli O157:H7 (EHEC) that can induce important infectious diseases, are highly on demand. Materials and Methods: In ...

متن کامل

تشخیص شاخص های Escherichia coli و Enterococcus faecalis در منابع آب

Microbial analysis of ground water, as the sole supplying water source in many areas, must be evaluated. Because the treatment of water cannot remove all pathogenic bacteria leaked from domestic wastewater, bacterial analysis of Bojnourd groundwater sources was performed. For this reason, membrane filter (MF) technique and Most Probable Number (MPN) method were used to evaluate the microbial qu...

متن کامل

Rapid and sensitive electrochemical detection of DNA with Silver nanoparticle dispersed poly (9, 9-dioctylfluorene-ran-phenylene) nanocomposites

In this study a sensitive electrochemical sensor for the detection of E.coli has been developed using silver nanoparticle (Ag) embedded poly(9,9-dioctylfluorene-ran-phenylene) (CFP) nanocomposite as a conductive platform and DNA hybridization technique. The new polymer was synthesized from 9,9-dioctylfluorene and 1,3-dichlorobenzene and biphenyl through Friedel Crafts alkylation reacti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2005