BACKGROUND Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100-200 μs) and low-to-moderate pulse frequencies (30-50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intensities and non-orderly recruitment of motor units. The use of both wide pulse widths (1000 μs) and tendon vibration might optimize motor unit activation through spinal reflex pathways and thus delay the onset of muscle fatigue, increasing muscle force and mass. Thus, the objective of this study was to examine the acute effects of patellar tendon vibration superimposed onto wide-pulse width (1000 μs) knee extensor electrical stimulation (NMES, 30 Hz) on peak muscle force, total impulse before "muscle fatigue", and the post-exercise recovery of muscle function. METHODS Tendon vibration (Vib), NMES (STIM) or NMES superimposed onto vibration (STIM + Vib) were applied in separate sessions to 16 healthy adults. Total torque-time integral (TTI), maximal voluntary contraction torque (MVIC) and indirect measures of muscle damage were tested before, immediately after, 1 h and 48 h after each stimulus. RESULTS TTI increased (145.0 ± 127.7%) in STIM only for "positive responders" to the tendon vibration (8/16 subjects), but decreased in "negative responders" (-43.5 ± 25.7%). MVIC (-8.7%) and rectus femoris electromyography (RF EMG) (-16.7%) decreased after STIM (group effect) for at least 1 h, but not after STIM + Vib. No changes were detected in indirect markers of muscle damage in any condition. CONCLUSIONS Tendon vibration superimposed onto wide-pulse width NMES increased TTI only in 8 of 16 subjects, but reduced voluntary force loss (fatigue) ubiquitously. Negative responders to tendon vibration may derive greater benefit from wide-pulse width NMES alone.
منابع مشابه
Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on muscle force production in people with spinal cord injury (SCI)
BACKGROUND Neuromuscular electrical stimulation (NMES) is commonly used in skeletal muscles in people with spinal cord injury (SCI) with the aim of increasing muscle recruitment and thus muscle force production. NMES has been conventionally used in clinical practice as functional electrical stimulation (FES), using low levels of evoked force that cannot optimally stimulate muscular strength and...
متن کاملAlteration of synergistic muscle activity following neuromuscular electrical stimulation of one muscle
The aim of the study was to determine muscle activation of the m. triceps surae during maximal voluntary contractions (MVCs) following neuromuscular electrical stimulation (NMES) of the m. gastrocnemius lateralis (GL). The participants (n = 10) performed three MVC during pretest, posttest, and recovery, respectively. Subsequent to the pretest, the GL was stimulated by NMES. During MVC, force an...
متن کاملInfluence of stimulus pulse width on M-waves, H-reflexes, and torque during tetanic low-intensity neuromuscular stimulation.
Neuromuscular electrical stimulation (NMES) has been shown to generate contractions that include a central recruitment of motoneurons; however, the effect of pulse width on electromyographic (EMG) and torque responses during NMES are not well documented. Soleus EMG and isometric plantarflexion torque were recorded from 14 subjects with NMES delivered to the tibial nerve using 50, 200, 500, and ...
متن کاملEffects of pulse duration on muscle fatigue during electrical stimulation inducing moderate-level contraction.
INTRODUCTION Neuromuscular electrical stimulation (NMES) is used to prevent muscle atrophy. However, the effect of pulse duration modulation for reducing muscle fatigue and pain is unknown. METHODS Two 2-minute stimulation protocols were applied to the knee extensors of 10 healthy individuals. In 1 session, a long pulse duration (1,000 μs) and a low current amplitude (LL), set to evoke 25% ma...
متن کاملMechanisms underlying the training effects associated with neuromuscular electrical stimulation.
Although neuromuscular electrical stimulation (NMES) can increase the ability of muscle to exert force, the means by which this is accomplished seem to be different from those associated with voluntary exercise. The aim of the study was to determine whether the recruitment order of motor units elicited by over-the-muscle electrical stimulation is different from that achieved with voluntary acti...