Development of a universal medical X‐ray imaging phantom prototype

نویسندگان

  • Annemari Groenewald
  • Willem A. Groenewald
چکیده

Diagnostic X-ray imaging depends on the maintenance of image quality that allows for proper diagnosis of medical conditions. Maintenance of image quality requires quality assurance programs on the various X-ray modalities, which consist of pro-jection radiography (including mobile X-ray units), fluoroscopy, mammography, and computed tomography (CT) scanning. Currently a variety of modality-specific phantoms are used to perform quality assurance (QA) tests. These phantoms are not only expensive, but suitably trained personnel are needed to successfully use them and interpret the results. The question arose as to whether a single universal phantom could be designed and applied to all of the X-ray imaging modalities. A universal phantom would reduce initial procurement cost, possibly reduce the time spent on QA procedures and simplify training of staff on the single device. The aim of the study was to design and manufacture a prototype of a universal phantom, suitable for image quality assurance in general X-rays, fluoroscopy, mammography, and CT scanning. The universal phantom should be easy to use and would enable automatic data analysis, pass/fail reporting, and corrective action recommendation. In addition, a universal phantom would especially be of value in low-income countries where finances and human resources are limited. The design process included a thorough investigation of commercially available phantoms. Image quality parameters necessary for image quality assurance in the different X-ray imaging modalities were determined. Based on information obtained from the above-mentioned investigations, a prototype of a universal phantom was developed, keeping ease of use and reduced cost in mind. A variety of possible phantom housing and insert materials were investigated, considering physical properties, machinability, and cost. A three-dimensional computer model of the first phantom prototype was used to manufacture the prototype housing and inserts. Some of the inserts were 3D-printed, others were machined from different materials. The different components were assembled to form the first prototype of the universal X-ray imaging phantom. The resulting prototype of the universal phantom conformed to the aims of a single phantom for multiple imag-ing modalities, which would be easy to use and manufacture at a reduced cost. A PCT International Patent Application No. PCT/IB2016/051165 has been filed for this technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medical Imaging Teacher: A Program to Simulate X-Ray Images of the Body by Considering kVp, mAs, and FFD Values

Introduction: Teaching styles and methods have been constantly changing in the recent years. In the 1980s and 90s, the world was introduced to various developed devices, such as smart boards and early generation smart phones that had an immediate innovative effect on education. These advancements has resulted in a considerable improvement in the current educational techniques. The innovations i...

متن کامل

Development and Characterization of Synthetic Tissue- Equivalent Material for CT Imaging Applications

Introduction: The use of a simple tissue analog material in the fabrication of medical computed tomography (CT) imaging phantoms has great potential to help researchers. The purpose of the present study is to develop new gel tissue-equivalent materials and determine whether their CT numbers and relative electron densities vary in CT images obtained by scans at different energie...

متن کامل

Development of a physical 3D anthropomorphic breast phantom.

PURPOSE Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. METHODS The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the vo...

متن کامل

Construction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography

Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...

متن کامل

Comparing X-ray dose reduction capability of silicon-bismuth micro- and nanocomposite shields using chest CT test

Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016