Impact of Decontamination Therapy on Ultrasound Visualization of Ingested Pills
نویسندگان
چکیده
INTRODUCTION Acute toxic ingestion is a common cause of morbidity and mortality. Emergency physicians (EP) caring for overdose (OD) patients are often required to make critical decisions with incomplete information. Point of care ultrasound (POCUS) may have a role in assisting EPs manage OD patients. We evaluated the impact of different liquid adjuncts used for gastric decontamination on examiners' ability to identify the presence of tablets using POCUS, and assessed examiners' ability to quantify the numbers of tablets in a simulated massive OD. METHODS This prospective, blinded, pilot study was performed at an academic emergency department. Study participants were volunteer resident and staff EPs trained in POCUS. Five nontransparent, sealed bags were prepared with the following contents: 1 liter (L) of water, 1 L of water with 50 regular aspirin (ASA) tablets, 1 L of water with 50 enteric-coated aspirin tablets (ECA), 1 L of polyethylene glycol (PEG) with 50 ECA, and 1 L of activated charcoal (AC) with 50 ECA. After performing POCUS on each of the bags using a 10-5 MHz linear array transducer, participants completed a standardized questionnaire composed of the following questions: (1) Were pills present? YES/NO; (2) If tablets were identified, estimate the number (1-10, 11-25, >25). We used a single test on proportions using the binomial distribution to determine if the number of EPs who identified tablets differed from 50% chance. For those tablets identified in the different solutions, another test on proportions was used to determine whether the type of solution made a difference. Since 3 options were available, we used a probability of 33.3%. RESULTS Thirty-seven EPs completed the study. All (37/37) EP's correctly identified the absence of tablets in the bag containing only water, and the presence of ECA in the bags containing water and PEG. For Part 2 of the study, most participants - 25/37 (67.5%) using water, 23/37 (62.1%) using PEG, and all 37 (100%) using AC - underestimated the number of ECA pills in solution by at least 50%. CONCLUSION There may be a potential role for POCUS in the evaluation of patients suspected of acute, massive ingested OD. EPs accurately identified the presence of ECA in water and PEG, but underestimated the number of tablets in all tested solutions.
منابع مشابه
Pnm-1: Applications of Hysterosonography for The Detection of Intracavitary Uterine Abnormalities
Hysterosonography (SHG) is a new noninvasive technique that involves the slow infusion of sterile saline solution into the uterus during ultrasound imaging. Expansion of endometrial cavity by SHG allows optimal visualization and plays an important role in the evaluation of abnormalities related to the uterus. The most common indications for hysterosonography are: abnormal uterine bleeding both ...
متن کاملI-49: Safely Extending Focused Ultrasound Surgery for Uterine Leiomyomas to Women Who Desire Future Pregnancies
Background: Focused ultrasound surgery (FUS) is a novel noninvasive surgery that results in localized tissue necrosis without any breech of the skin or other body orifice. MRI guidance provides anatomic visualization and real time thermal feedback. Our goal is to safely extend this therapy to women who desire future pregnancies. Materials and Methods: We have undertaken 4 multisite trials of FU...
متن کاملThe Impact of Visualization and Graphic Organizers on EFL Learners’ Cognitive, Emotional, and Behavioral Engagement and Listening
The present study examined the impact of visualization and graphic organizers as pre-listening strategies on English as a foreign language (EFL) learners’ cognitive, behavioral, and emotional engagement and their listening comprehension. To do so, this study was carried out in three listening classes at Islamic Azad University of Mashhad. The participants included 80 junior EFL university stude...
متن کاملدیداری کردن نتایج جستوجو در فرایند بازیابی اطلاعات
Purpose: One of the most effective ways to achieve optimum information retrieval is through visualization of Information. Search strategies, probing skills, querying of information needs and analysis of information play a significant role in the accessing of necessary and useful information. Besides the factors mentioned above, information visualization can increase the availability level of in...
متن کاملAn overview of therapeutic applications of ultrasound based on synergetic effects with gold nanoparticles and laser excitation
Acoustic cavitation which occurs at high intensities of ultrasound waves can be fatal for tumor cells. The existence of dissolved gases and also the presence of nanoparticles (NPs) in a liquid, irradiated by ultrasound, decrease the acoustic cavitation onset threshold and the resulting bubbles collapse. On the other hand, due to unique capabilities and optical properties of gold nanoparticles (...
متن کامل