An ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load.

نویسندگان

  • Stephen M Belkoff
  • Louis E Jasper
  • Sheila S Stevens
چکیده

STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVE To determine if fracture reduction could be achieved by the inflatable bone tamp (tamp) in vertebral bodies under simulated physiologic loads. SUMMARY OF BACKGROUND DATA Previous ex vivo biomechanical studies showed that kyphoplasty restored vertebral body height with vertebral body endplates under stress-free conditions. METHODS Simulated compression fractures were experimentally created in 18 osteoporotic vertebral bodies alternatingly assigned to one of two treatment (tamp inflation) groups: low axial load (111 N) or high axial load (222 N). Each vertebral body was then placed between two platens in a special radiolucent loading fixture and subjected to the preassigned load to simulate in vivo physiologic loading. The tamps were inflated and postreduction heights were measured fluoroscopically. The effect of applied load and condition on vertebral body height was checked for significance (P < 0.05). RESULTS Comparing the experimental conditions (initial, postcompression, postinflation), there were no significant vertebral body height differences between the load groups (low load vs. high load). However, vertebral body height differences between conditions within each load group were all significant. For the low-load and high-load groups, mean postinflation heights (24.4 and 24.4 mm) were significantly greater than mean postcompression heights (21.6 and 22.5 mm) but significantly less than initial vertebral body heights (26.6 and 26.3 mm), respectively. Initial heights were fully restored in 22% (two of nine) of vertebral bodies in both groups. CONCLUSION The inflatable bone tamp restored some of the height lost to compression fractures in vertebral bodies under simulated physiologic loads.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture.

STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVES To determine if the inflatable bone tamp (tamp) restores height to compressed vertebral bodies and to compare the biomechanical properties of isolated, fractured osteoporotic vertebral bodies treated by kyphoplasty (tamp) or vertebroplasty. SUMMARY OF BACKGROUND DATA Previous biomechanical stu...

متن کامل

Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

STUDY DESIGN An Institutional Review Board-approved Phase I efficacy study of inflatable bone tamp usage in the treatment of symptomatic osteoporotic compression fractures. OBJECTIVES To evaluate the safety and efficacy of inflatable bone tamp reduction and cement augmentation, "kyphoplasty," in the treatment of painful osteoporotic vertebral compression fractures. SUMMARY OF BACKGROUND DAT...

متن کامل

Radiofrequency-targeted vertebral augmentation versus traditional balloon kyphoplasty: radiographic and morphologic outcomes of an ex vivo biomechanical pilot study [Erratum]

PURPOSE Traditional balloon kyphoplasty (BK) is a common treatment for symptomatic vertebral compression fractures. The purpose of this study was to compare a novel vertebral augmentation technique, radiofrequency-targeted vertebral augmentation (RF-TVA), to BK for restoration of vertebral height, cavity creation, and polymethylmethacrylate (PMMA) delivery and interdigitation into the surroundi...

متن کامل

A biomechanical comparison of kyphoplasty using a balloon bone tamp versus an expandable polymer bone tamp in a deer spine model.

We performed a biomechanical study to compare the augmentation of isolated fractured vertebral bodies using two different bone tamps. Compression fractures were created in 21 vertebral bodies harvested from red deer after determining their initial strength and stiffness, which was then assessed after standardised bipedicular vertebral augmentation using a balloon or an expandable polymer bone t...

متن کامل

An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty.

BACKGROUND AND PURPOSE Previous ex vivo biomechanical studies have shown that kyphoplasty with polymethylmethacrylate cement increases vertebral body (VB) strength and restores VB stiffness and height after compression fracture. The purpose of the current study was to determine if a hydroxyapatite cement used as a void filler during kyphoplasty provides mechanical stabilization similar to that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Spine

دوره 27 15  شماره 

صفحات  -

تاریخ انتشار 2002