Neonatal volume guarantee ventilation: effects of spontaneous breathing, triggered and untriggered inflations.

نویسندگان

  • N McCallion
  • R Lau
  • C J Morley
  • P A Dargaville
چکیده

BACKGROUND During volume guarantee (VG) ventilation the peak inflating pressure (PIP) for each ventilator inflation is adjusted to ensure the expired tidal volume (V(Te)) is close to the set V(Te). Differences in the PIP between inflations triggered by the infant's inspirations and untriggered inflations are seen. AIM To investigate the effects of triggered and untriggered inflations on PIP and V(Te). METHODS Neonates were ventilated with the Dräger Babylog 8000 using assist control (synchronous intermittent positive pressure ventilation) and VG modes. Continuous recordings of ventilator pressures and tidal volumes were made at 200 Hz for 10 minutes. RESULTS In 10 infants, 6540 inflations were analysed, of which 4052 (62%) were triggered. Triggered inflations had a significantly lower mean (SD) PIP than untriggered inflations: 12.9 (4.9) vs 17.0 (3.3) cm H2O, (p<0.001). Despite this, there was no significant difference in the V(Te) of each type of inflation (103% and 101% of the set V(Te), respectively). When a triggered inflation was immediately preceded or followed by an untriggered inflation the PIP changed by about 5 cm H2O. Between adjacent inflations of the same type, the change in PIP was less than 3 cm H2O: for triggered inflations it was 0.11 (1.50) cm H2O and for untriggered inflations 0.06 (1.53) cm H2O. CONCLUSION During VG ventilation with the Dräger Babylog 8000 the PIP was 4 cm H2O lower during triggered inflations than untriggered inflations, although the expired tidal volumes were similar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volume guarantee ventilation, interrupted expiration, and expiratory braking.

BACKGROUND In volume guarantee ventilation with the Dräger Babylog 8000 ventilator, inspiratory and expiratory flows are monitored and the expiratory tidal volume calculated following each inflation. The pressure for the next inflation is modified to ensure the expired tidal volume is close to the set value. AIM To investigate interrupted expiration observed during volume guarantee ventilatio...

متن کامل

Effective Strategy for Newborn Screening for Congenital Hypothyroidism.

2. Infants can actively tighten their abdominal muscles that can prevent gas entering the lungs during inflation; often termed ‘splinting’ [3]. Forced expiration and splinting cause hypoxemic episodes due to low lung volume and low VT delivery, causing obstruction’ and ‘low VT’ alarms. Fig. 1 shows a recording from a 1000-g baby ventilated with assist control (AC) and VG ventilation at a rate o...

متن کامل

Surfactant Administration via Thin Catheter during Spontaneous Breathing: Randomized Controlled Trial in Alzahra hospital

Introduction Respiratory distress syndrome (RDS) is a current cause of morbidity in premature infants resulted from surfactant deficiency. The primary aim of this randomized study was to describe the feasibility of early administration of surfactant via a thin catheter during spontaneous breathing (TEC) and compare its outcomes with the InSurE (Intubate, Surfactant, Extubate) procedure Material...

متن کامل

A lightweight mainstream capnometer with very low dead space volume is useful monitor for neonates with spontanous and mechanical ventilation: Pilot study

Objects: The purpose of this study was to observe a correlation between PETCO2 and PaCO2 in intubated neonates under intermittent mandatory ventilation with spontaneous breathing. Material and methods: A total of 55 paired PETCO2 measured by mainstream capnometry and PaCO2 values were obtained from 4 intubated neonates in our neonatal intensive care units at Nagano Children’s Hospital, Nagano, ...

متن کامل

Neonatal patient triggered ventilation.

Patient triggered ventilation was assessed in 14 neonates (gestational age 24-40 weeks). Inspiratory changes in airflow, monitored by a pneumotachograph, were used to trigger the ventilator and this was not associated with complications. Patient triggered ventilation was maintained for up to eight hours (mean duration five hours). In 13 of 14 infants oxygenation improved and this was associated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 93 1  شماره 

صفحات  -

تاریخ انتشار 2008