Overdrive pacing from downstream sites on multielectrode catheters to rapidly detect fusion and to diagnose macroreentrant atrial arrhythmias.

نویسندگان

  • Chirag R Barbhaiya
  • Saurabh Kumar
  • Justin Ng
  • Usha Tedrow
  • Bruce Koplan
  • Roy John
  • Laurence M Epstein
  • William G Stevenson
  • Gregory F Michaud
چکیده

BACKGROUND Entrainment criteria for macroreentrant arrhythmias are based on detecting fusion between tachycardia and paced wavefronts, but this is often difficult for atrial tachycardias (AT) after ablation of atrial fibrillation. METHODS AND RESULTS With the use of a multipolar catheter, pacing was performed from electrodes within the coronary sinus showing activation later than adjacent electrodes (downstream overdrive pacing) during 66 ATs in 62 patients: 20 cavotricuspid isthmus-dependent ATs, 20 perimitral ATs, 13 focal ATs with sequential coronary sinus activation, and 13 other macroreentrant left atrial ATs. The paced cycle length was 10 to 30 milliseconds below the tachycardia cycle length (TCL), and activation at the neighboring upstream electrodes was assessed. Downstream overdrive pacing at 48 sites close to a macroreentrant circuit (PPI-TCL <40 milliseconds, where PPI is postpacing interval) produced constant fusion demonstrated by a long stimulus to upstream atrial electrogram interval (S-Au) >75% TCL and was consistent with orthodromic activation of the upstream site despite its close proximity to the pacing site. In contrast, downstream overdrive pacing at 18 sites during focal AT or remote from the macroreentrant AT circuit (PPI-TCL >40 milliseconds) always demonstrated a comparatively short S-Au <25% of TCL (12±4% versus 89±4% of TCL; P<0.001), consistent with direct activation. CONCLUSIONS Selection of a downstream activation site for overdrive pacing can facilitate rapid recognition of macroreentry and proximity to the reentry circuit using a single multielectrode catheter by recognizing a PPI-TCL <40 milliseconds and S-Au >75% of TCL. Recognition of intracardiac constant fusion with this method is a novel criterion for transient entrainment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical experience with a novel multielectrode basket catheter in right atrial tachycardias.

BACKGROUND The complexity of atrial tachycardias (ATs) makes the electroanatomic characterization of the arrhythmogenic substrate difficult with conventional mapping techniques. The aim of our study was to evaluate possible advantages of a novel multielectrode basket catheter (MBC) in patients with AT. METHODS AND RESULTS In 31 patients with AT, an MBC composed of 64 electrodes was deployed i...

متن کامل

Biatrial Tachycardia

The approach to successful ablation of arrhythmias is based on elucidating the underlying mechanism and relative dimensions of the tachycardia circuit. Activation mapping readily distinguishes macroreentry from focal arrhythmias, the latter of which have centrifugal spread. When macroreentrant atrial tachycardia is suspected, entrainment maneuvers with atrial overdrive pacing at various anatomi...

متن کامل

The response to overdrive pacing of triggered atrial and ventricular arrhythmias in the canine heart.

Although triggered activity has been identified in isolated atrial tissue with the use of cellular electrophysiologic techniques, there has been no identification of triggered atrial arrhythmias in situ. Moreover, it is unclear whether triggered rhythms of different causes and sites of origin in the heart exhibit uniform responses to pacing that might aid in their identification. We therefore s...

متن کامل

High-resolution mapping of scar-related atrial arrhythmias using smaller electrodes with closer interelectrode spacing.

BACKGROUND The resolution of mapping is influenced by electrode size and interelectrode spacing. Smaller electrodes with closer interelectrode spacing may improve mapping resolution, particularly in scar. The aims of this study were to establish normal electrogram criteria in the atria for both 3.5-mm electrode tip linear catheters (Thermocool) and 1-mm multielectrode-mapping catheters (Pentara...

متن کامل

Is there a role for pacing in the prevention of atrial tachyarrhythmias?

In this issue of EUROPACE, Blanc et al. [1] present data from one of the five PIPAF (Pacing in Prevention of Atrial Fibrillation) studies which assess the effects of pacing on prevention of atrial tachyarrhythmias (ATs) using different atrial pacing sites (conventional sites, septal, dual site right atrial and biatrial) alone or in combination with one or more dedicated pacing algorithms [2]. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 129 24  شماره 

صفحات  -

تاریخ انتشار 2014