Performance and Pitfalls of Diagnostic X-ray Sources: an Overview

نویسنده

  • R. Behling
چکیده

Performance and reliability of medical X-ray sources for imaging humans are crucial from ethical, clinical and economic perspectives. This overview will treat the aspects to consider for investment of equipment for medical X-ray imaging. Recent X-ray tubes deliver enhanced reliability and unprecedented performance. But, metric for benchmarking has to change. Modern terms for product comparison still need to penetrate the market and to be implemented in practice. It is time to abandon heat units and comply with latest standards, which consider current technology. In view of the increasing number of interventional procedures and the risks associated with ionizing radiation, toxic contrast agents, and the potentially hazardous combination thereof, system reliability is of paramount importance. This paper will discuss tube life time aspects. The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains high. Still, system developers and clinicians suffer from gaps between aspirations and reality in day-to-day diagnostic routine. Xray sources are still limiting cutting-edge medical procedures. Undesired side-effects, wear and tear, limitations of the clinical work flow, costs, and undesired characteristics of the X-ray source must be further addressed. New applications and modalities, like spectral CT, and phase-contrast or dark-field imaging will impact the course of new developments of X-ray sources. High performance and flawless operation of the very special kind of vacuum electronics of X-ray tubes can only be safeguarded by quality manufacturing and highly skilled craftsmanship. Joint development of semiconductor and vacuum based electronics, i.e. X-ray generators and tubes, has proven key to success in the medical industry to guarantee a seamless match of the once separate devices. Thus, the terminology is expected to morph from X-ray tube and high-voltage generator to X-ray source segment. Keywords— X-ray tube, X-ray generator, tube failures, Xray tube metric, reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea

  Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

An Enumeration Survey on Diagnostic X-Ray Generators and Essential Safety Parameters in Mizoram, India

Introduction: Best radiography practice involves operational optimal machine performance, delivering cost-effective healthcare services under appropriate safety conditions for workers and the public. The present study aimed to investigate the safety status of diagnostic X-ray installations in Mizoram, India. Material and Methods: Lineari...

متن کامل

Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Materials and Methods: A total of 2382 patients were studied t...