Factors Affecting Intracanal Instrument Fracture
نویسندگان
چکیده
منابع مشابه
Management of an Intracanal Separated Instrument: A Case Report
Instrument fracture within the root canal during root canal treatment is an unwanted and frustrating complication. The fractured segment may hinder cleaning and shaping procedures with potential impact on prognosis of treatment. Fracture of endodontic instrument often results from incorrect use or overuse. If breakage occurs clinically, the patient should be informed of the incident and conside...
متن کاملTips to avoid instrument separation in endodontics.
procedural accidents and obstacles to normally routine therapy, at almost any stage of treatment. One of these procedural problems is intracanal instrument fracture. Fractured root canal instruments may include endodontic files (Figure 1) and Gates Glidden burs. Instruments are made from nickel titanium (NiTi), stainless steel or carbon steel. Fracture often results from incorrect use or overus...
متن کاملRationale for the use of low-torque endodontic motors in root canal instrumentation.
Fracture of nickel-titanium rotary files is an iatrogenic error which can seriously jeopardize root canal therapy. If a high-torque motor is used, the instrument-specific limit-torque (fracture limit) is often exceeded, thus increasing the risk of intracanal failure. A possible solution to this problem is to use a low-torque endodontic motor which operates below these values. If the torque is s...
متن کاملCalcium hydroxide intracanal dressing removal with different rotary instruments and irrigating solutions: a scanning electron microscopy study.
This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. A...
متن کاملEffect of Amperage and Field of View on Detection of Vertical Root Fracture in Teeth with Intracanal Posts
INTRODUCTION This study sought to assess the effects of amperage (mA) and field of view (FOV) on intracanal metal post artifacts and the diagnostic parameters for detection of vertical root fracture (VRF) in teeth with intracanal posts. METHODS AND MATERIALS In this diagnostic study, 80 human single-canal teeth were evaluated by cone-beam computed tomography (CBCT). Nickel chrome cast posts w...