Collection of WBC-reduced single-donor PLT concentrates with a new blood cell separator: results of a multicenter study.

نویسندگان

  • Rainer Moog
  • Thomas Zeiler
  • Hans-Gert Heuft
  • Bernhard Stephan
  • Eike G Fischer
  • Volker Kretschmer
  • Regina Rödel-Spieker
  • Erwin Strasser
  • Jürgen Zingsem
چکیده

BACKGROUND A new cell separator (COM.TEC, Fresenius) was recently developed aimed at efficient collection of WBC-reduced single-donor PLT concentrates (SDPs). STUDY DESIGN AND METHODS Five German centers collected 554 WBC-reduced SDPs with help of the COM.TEC cell separator. Two multicenter cell counting studies were performed at the beginning and at the end of the study to document uniform counting results among the participating centers. RESULTS A total of 441 (79.6%) PLT collections were included in the study according to the protocol. A total of 342 single-dose and 99 double-dose SDPs were collected. For single-dose SDPs, an average blood volume of 2826 +/- 409 mL was processed in a donation time of 55 +/- 11 minutes. Mean PLT yield of these products was 3.11 x 1011+/- 0.40 x 1011 and the WBC contamination was 0.11 x 106+/- 0.20 x 106. For double-dose SDPs (PLT count, 5.29 +/- 0.93 x 1011), 3943 +/- 639 mL was processed. The average difference between the target and the collected PLT concentration was -2.8 +/- 12.0 percent for single-dose SDPs and -1.8 +/- 9.5 for double-dose SDPs, respectively. The collection efficiency was 53.7 +/- 5.8 percent for single-dose SDPs and 58.2 +/- 6.2 percent for double-dose SDPs. If all results of each sample from the counting study were set to unity (to the mean over all centers), most PLT determinations were very similar to the mean, for example, near or 1 if set to unity. CONCLUSION The COM.TEC machine makes it possible to obtain WBC-reduced SDPs that comply with current standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Indian initiative for preparation of low-titer group “O” single-donor platelets with platelet additive solution

BACKGROUND Guidelines recommend ABO-identical platelet (PLT) transfusions. Hemolytic reactions after a minor ABO-incompatible PLT transfusion have escalated due to single-donor platelets (SDP) containing ABO-incompatible plasma. Avoiding such events by examining titers or performing plasma reduction is cumbersome. The introduction of platelet additive solutions (PAS) has enabled to reduce these...

متن کامل

بررسی اثر انواع الگوهای هایپرلیپیدمی بر نتایج شمارش کامل سلول‌های خونی: یک مطالعه مورد ـ ‌شاهدی

Background and Objective: Despite the speed and accuracy of cell counting devices in the analysis of blood samples, several confounding factors may influence their outcomes. This study was performed to assess the effect of hyperlipidemia patterns on the results of complete blood cell count (CBC). Materials and Methods: This analytical study (case-control) was performed among 306 non-diabetic a...

متن کامل

Comparison of Plateletpheresis on the Fenwal Amicus and Fresenius Com.Tec Cell Separators.

SUMMARY: BACKGROUND: A variety of apheresis devices are now available on the market for plateletapheresis. We compared two apheresis instruments (Fenwal Amicus and Fresenius COM.TEC) with regard to processing time, platelet (PLT) yield and efficiency, and white blood cell (WBC) content. MATERIAL AND METHODS: Donors undergoing plateletpheresis were randomly separated into two groups (either the ...

متن کامل

Adherence to the Mediterranean diet is associated with lower platelet and leukocyte counts: results from the Moli-sani study.

Platelet (PLT) and white blood cell (WBC) counts are 2 markers of inflammation and have been linked to the risk for cerebrovascular and coronary heart disease. A Mediterranean diet (MD) has been associated with reduced inflammation and mortality for major chronic diseases. We aimed at evaluating the association between the MD and both PLT and WBC counts. This cross-sectional analysis in a popul...

متن کامل

Analysis of platelet-derived extracellular vesicles in plateletpheresis concentrates: a multicenter study.

BACKGROUND Routine quantification of platelet-derived extracellular vesicles (PL-EVs) may be useful in the quality control (QC) of platelet concentrates (PCs). The aim of this multicenter study was to establish and validate a consensus protocol for the standardized PL-EV quantification using conventional flow cytometers. STUDY DESIGN AMD METHODS Eighty-six PCs were investigated in five blood ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transfusion

دوره 43 8  شماره 

صفحات  -

تاریخ انتشار 2003