Evaluation of enzyme immunoassay and radioimmunoassay methods for the measurement of plasma oxytocin.

نویسندگان

  • Angela Szeto
  • Philip M McCabe
  • Daniel A Nation
  • Benjamin A Tabak
  • Maria A Rossetti
  • Michael E McCullough
  • Neil Schneiderman
  • Armando J Mendez
چکیده

OBJECTIVE There is increased interest in measuring peripheral oxytocin levels to better understand the role of this peptide in mammalian behavior, physiology, and disease. The purpose of this study was to compare methods for plasma oxytocin measurement using a commercially available enzyme immunoassay (EIA) and radioimmunoassay (RIA), to evaluate the need for sample extraction, and to assess the immunospecificity of the assays. METHODS Oxytocin was measured in extracted and unextracted human plasma samples (n = 39). Oxytocin and its degradation products were separated by high-performance liquid chromatography and gel filtration chromatography and then assayed by EIA or RIA to identify oxytocin immunoreactive peaks. RESULTS Without extraction, plasma measured by EIA was more than 100-fold higher than in extracted plasma, and the correlation between oxytocin levels in extracted and unextracted plasma was minimal (Spearman ρ = -0.10, p = .54). Using the RIA, most samples (>90%) were below the level of detection with or without extraction. After chromatographic fractionation of sample extracts, multiple immunoreactive products were found to be present in addition to oxytocin, which casts doubts on the specificity of the assays. CONCLUSIONS Changes in oxytocin levels have been reported in social and behavioral challenge studies. This study indicates that sample extraction is necessary to obtain valid assay results. Changes in oxytocin degradation products are likely to contribute to the previously observed responses in circulating oxytocin levels to behavioral and social challenge. There is a critical need for valid and reliable methods to measure oxytocin in biologic samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enzyme immunoassay for oxytocin.

A competitive, double antibody enzyme immunoassay for oxytocin in a heterologous system was developed. Horseradish peroxidase was conjugated with oxytocin using N-succinimidyl 3-(2-pyridyldithio) propionate, and rabbit anti-oxytocin serum was produced by immunization of oxytocin-bovine serum albumin complex which was prepared by the carbodiimide method. The sensitivity of the assay was 4 microI...

متن کامل

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES

Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...

متن کامل

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Psychosomatic medicine

دوره 73 5  شماره 

صفحات  -

تاریخ انتشار 2011