Flow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics

نویسندگان

  • Kambiz Shahgaldi
  • Emil Söderqvist
  • Petri Gudmundsson
  • Reidar Winter
  • Jacek Nowak
  • Lars-Åke Brodin
چکیده

BACKGROUND This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities. METHODS Thirty-one patients with moderate-severe aortic (AS) and mitral (MS) stenoses (21 and 10 patients, respectively) and 10 healthy volunteers underwent 3D echocardiography with full volume acquisition using Philips Sonos 7500 equipment. The digital 3D data were post- processed using TomTec software. LV flow-volume loops were subsequently constructed for each subject by plotting instantaneous LV volume data sampled throughout the cardiac cycle vs. their first derivative representing LV flow. After correction for body surface area, an average flow-volume loop was calculated for each subject group. RESULTS Flow-volume loops were obtainable in all subjects, except 3 patients with AS. The flow-volume diagrams displayed clear differences in the form and position of the loops between normal individuals and the respective patient groups. In patients with AS, an "obstructive" pattern was observed, with lower flow values during early systole and larger end-systolic volume. On the other hand, patients with MS displayed a "restrictive" flow-volume pattern, with reduced diastolic filling and smaller end-diastolic volume. CONCLUSION Non-invasive evaluation of LV flow-volume dynamics using 3D-echocardiographic data is technically possible and the approach has a capacity to identify certain specific types of alteration of LV flow-volume pattern caused by valvular abnormalities, thus reflecting underlying hemodynamic states specific for these abnormalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Left Ventricular Function and Hemodynamics using Three-dimensional Echocardiography

................................................................................................................................. iii LIST OF PUBLICATIONS ......................................................................................................... v DIVISION OF WORK BETWEEN AUTHORS ..................................................................... vii SCIENTIFIC CONTRIBUTIONS NO...

متن کامل

Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.

AIMS Two-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular outflow tract (LVOT) velocity and geometric assumptions of LVOT area, which can amplify error, especially in upper septal hypertrophy (USH). We hypothesized that real-time three-dimensional echocardiography (RT3DE) ca...

متن کامل

Feasibility of Computational Fluid Dynamics for Evaluating the Intraventricular Hemodynamics in Single Right Ventricle Based on Echocardiographic Images

This study introduced a combined computational fluid dynamics (CFD) and echocardiography methodology to simulate blood flow in the single right ventricle (SRV) and normal ventricles to study the intraventricular flow. Derived from echocardiographic image loops, CFD-based three-dimensional (3D) flow models of normal subject's left ventricle (LV) and right ventricle (RV) and SRV with and without ...

متن کامل

Assessment of aortic stenosis severity by rest CMR correlates well with stress echocardiography in the setting of low left ventricular flow states

Background Identifying the high-risk subset of patients with severe aortic stenosis (AS) and low transvalvular pressure gradient due to significant left ventricular (LV) impairment has relied on the assessment of the haemodynamic changes in response to flow normalization using pharmacological stress. Although cardiovascular magnetic resonance (CMR) aortic valve area (AVA) derived from planimetr...

متن کامل

Three-dimensional echocardiography. In vivo validation for left ventricular volume and function.

BACKGROUND Current two-dimensional quantitative echocardiographic methods of volume assessment require image acquisition from standardized scanning planes. Left ventricular volume and ejection fraction are then calculated by assuming ventricular symmetry and geometry. These assumptions may not be valid in distorted ventricles. Three-dimensional echocardiography can quantify left ventricular vol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2008