Cavity beam position monitor system for the Accelerator Test Facility 2
نویسندگان
چکیده
Y. I. Kim, R. Ainsworth, A. Aryshev, S. T. Boogert,* G. Boorman, J. Frisch, A. Heo, Y. Honda, W.H. Hwang, J. Y. Huang, E-S. Kim, S. H. Kim, A. Lyapin, T. Naito, J. May, D. McCormick, R. E. Mellor, S. Molloy, J. Nelson, S. J. Park, Y. J. Park, M. Ross, S. Shin, C. Swinson, T. Smith, N. Terunuma, T. Tauchi, J. Urakawa, and G. R. White Kyungpook National University, Daegu, Korea John Adams Institute at Royal Holloway, University of London, Egham, United Kingdom KEK, Tsukuba, Japan SLAC National Accelerator Laboratory, Menlo Park, California 94025-7015, USA Pohang Accelerator Laboratory, Pohang, Korea Laboratory for Elementary-Particle Physics, Cornell University, Ithaca, New York 14853-8001, USA Fermi National Accelerator Laboratory, Batavia, Illinois 60510-5011, USA Brookhaven National Laboratory, Upton, New York 11973-5000, USA (Received 7 October 2011; published 10 April 2012)
منابع مشابه
High Precision Sc Cavity Diagnostics with Hom Measurements
Experiments at the FLASH linac at DESY have demonstrated that the Higher Order Modes induced in Superconducting Cavities can be used to provide a variety of beam and cavity diagnostics. The centers of the cavities can be determined from the beam orbit which produces minimum power in the dipole HOM modes. The phase and amplitude of the dipole modes can be used as a high resolution beam position ...
متن کاملHigh-Brightness Electron Beam Diagnostics at the ATF*
The Brookhaven Accelerator Test Facility (ATF) is a dedicated user facility for accelerator physicists. Its design is optimized to explore laser acceleration and coherent radiation production. To characterize the lowemittance, picoseconds long electron beam produced by the ATF's photocathode RF gun, we have installed electron beam profile monitors for transverse emittance measurement, and devel...
متن کاملStatus of the Re-entrant Cavity Beam Position Monitor for the European Xfel Project
The European XFEL is a research facility, currently under construction in Germany. It is based on a superconducting electron linac including about 100 cryomodules based on the TESLA technology. Each cryomodule is equipped with a beam position monitor connected to a quadrupole at the high-energy end of the cavity string. Around one third of cold BPMs will be reentrant RF cavities. This contribut...
متن کاملDesign of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretched-wire RF measurements
The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-μm regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical cen...
متن کاملCavity-type Beam Position Monitors for the SASE FEL at the TESLA Test Facility
Cavity-type beam position monitors were developed to measure the beam alignment at the undulator section of DESY’s TESLA Test Facility (TTF). This paper describes some theoretical aspects and the experimental setup. The results of some in-beam measurements at the TTF are presented and pros and cons of the monitor concept are discussed.
متن کاملDevelopment of a Beam Loss Detection System for the CLIC Test Facility 3
The CLIC test facility 3 (CTF3) provides a 3.5A, 1.6μs electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to time transients of beam position, size and energy along the pulse. To compensate for these transient...