Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode

نویسندگان

  • R Phillip Dellinger
  • Smith Jean
  • Ismail Cinel
  • Christina Tay
  • Susmita Rajanala
  • Yael A Glickman
  • Joseph E Parrillo
چکیده

INTRODUCTION There are several ventilator modes that are used for maintenance mechanical ventilation but no conclusive evidence that one mode of ventilation is better than another. Vibration response imaging is a novel bedside imaging technique that displays vibration energy of lung sounds generated during the respiratory cycle as a real-time structural and functional image of the respiration process. In this study, we objectively evaluated the differences in regional lung vibration during different modes of mechanical ventilation by means of this new technology. METHODS Vibration response imaging was performed on 38 patients on assist volume control, assist pressure control, and pressure support modes of mechanical ventilation with constant tidal volumes. Images and vibration intensities of three lung regions at maximal inspiration were analyzed. RESULTS There was a significant increase in overall geographical area (p < 0.001) and vibration intensity (p < 0.02) in pressure control and pressure support (greatest in pressure support), compared to volume control, when each patient served as his or her own control while targeting the same tidal volume in each mode. This increase in geographical area and vibration intensity occurred primarily in the lower lung regions. The relative percentage increases were 28.5% from volume control to pressure support and 18.8% from volume control to pressure control (p < 0.05). Concomitantly, the areas of the image in the middle lung regions decreased by 3.6% from volume control to pressure support and by 3.7% from volume control to pressure control (p < 0.05). In addition, analysis of regional vibration intensity showed a 35.5% relative percentage increase in the lower region with pressure support versus volume control (p < 0.05). CONCLUSION Pressure support and (to a lesser extent) pressure control modes cause a shift of vibration toward lower lung regions compared to volume control when tidal volumes are held constant. Better patient synchronization with the ventilator, greater downward movement of the diaphragm, and decelerating flow waveform are potential physiologic explanations for the redistribution of vibration energy to lower lung regions in pressure-targeted modes of mechanical ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibration Analysis of FG Nanoplate Based on Third-Order Shear Deformation Theory (TSDT) and Nonlocal Elasticity

In present study, the third-order shear deformation theory has been developed to investigate vibration analysis of FG Nano-plates based on Eringen nonlocal elasticity theory. The materials distribution regarding to the thickness of Nano-plate has been considered based on two different models of power function and exponential function. All equations governing on the vibration of FG Nano-plate ha...

متن کامل

Lung volume distribution in prolonged mechanical ventilation patients from assist control mode to spontaneous trial mode of automatic tubing compensation in electrical impedance tomography

Introduction Electrical impedance tomography (EIT) is a non-invasive and portable lung imaging technique for dynamic evaluation of lung volume distribution. Previous studies had proved the EIT can provide information on regional distribution of ventilation and changes in end-expiratory lung volume (△EELV). The effect of EIT application in ventilation distribution of prolonged mechanical ventila...

متن کامل

Suppressing Vibration In A Plate Using Particle Swarm Optimization

In this paper a mesh-free model of the functionally graded material (FGM) plate is presented.  The piezoelectric material as a sensor and actuator has been distributed on the top and bottom of the plate, respectively. The formulation of the problem is based on the classical laminated plate theory (CLPT) and the principle of virtual displacements. Moreover, the Particle Swarm optimization (PSO) ...

متن کامل

Compact and Efficient Active Vibro-acoustic Control of a Smart Plate Structure

An effective wide band active control law through one kind of the Dynamic Vibration Absorber (DVA) is proposed and studied in this paper. With the help of mechanical impedance method, active DVA control law is formulated based on the passive mechanical model. The electrical DVA can generate multi-mode active damping to the structure. The host structure is an aluminum plate and acceleration sign...

متن کامل

استفاده همزمان از دو ونتیلاتور برای درمان عوارض ریوی ناشی از تهویه مکانیکی در بیمار مولتیپل تروما: گزارش مورد

Background and Objective: Some of multiple trauma patients admitted in ICU (Intensive Care Unit) are intubated and ventilated by mechanical ventilation. These patients are prone to many complications such as lung disease. Reasons for this complication are patients without any movement, incomplete cough reflex, GI aspiration and then not a good pulmonary discharge prone the lungs of patients to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2007