An improved segmentation algorithm for quantification of myocardial infarction in contrast enhanced CMR images - validated in ex-vivo studies
نویسندگان
چکیده
Background T1-weighted contrast enhanced CMR images of explanted hearts in experimental studies provide a high resolution reference standard for quantification of myocardial infarction. Manual delineation is considered the reference standard, however it is time consuming and observer dependent. Especially since a data set may consist of more than 150 images with a resolution of typically 0.5×0.5×0.5 mm. Previous studies have used an algorithm for infarct quantification based on a fix number of 8 standard deviations (SD) from remote with manual corrections if necessary [1]. This algorithm may fail if images have different contrast to noise ratio, and is time consuming as the user needs to draw regions of interest in each slice. Therefore, the aim of this study was to provide a fully automated segmentation algorithm for quantification of myocardial infarction in T1-weighted contrast enhanced high resolution ex-vivo images.
منابع مشابه
Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
BACKGROUND Accurate assessment of myocardium at risk (MaR) after acute myocardial infarction (AMI) is necessary when assessing myocardial salvage. Contrast-enhanced steady-state free precession (CE-SSFP) is a recently developed cardiovascular magnetic resonance (CMR) method for assessment of MaR up to 1 week after AMI. Our aim was to validate CE-SSFP for determination of MaR in an experimental ...
متن کاملA new automatic algorithm for quantification of myocardial infarction imaged by late gadolinium enhancement cardiovascular magnetic resonance: experimental validation and comparison to expert delineations in multi-center, multi-vendor patient data.
BACKGROUND Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) using magnitude inversion recovery (IR) or phase sensitive inversion recovery (PSIR) has become clinical standard for assessment of myocardial infarction (MI). However, there is no clinical standard for quantification of MI even though multiple methods have been proposed. Simple thresholds have yielded varying ...
متن کاملT2-STIR CMR imaging can be used to assess myocardium at risk with gadolinium present in an experimental setting
Background In the situation of an acute coronary occlusion, the myocardium supplied by the affected artery becomes ischemic. This part of the myocardium is at risk of developing infarction unless reperfusion occurs, and is therefore referred to as the myocardium at risk (MaR). Myocardium at risk and infarct size can be used to calculate myocardial salvage when evaluating efficacy of interventio...
متن کاملRegional contrast agent quantification in a mouse model of myocardial infarction using 3D cardiac T1 mapping
BACKGROUND Quantitative relaxation time measurements by cardiovascular magnetic resonance (CMR) are of paramount importance in contrast-enhanced studies of experimental myocardial infarction. First, compared to qualitative measurements based on signal intensity changes, they are less sensitive to specific parameter choices, thereby allowing for better comparison between different studies or dur...
متن کاملInfarct quantification using 3D inversion recovery and 2D phase sensitive inversion recovery, validation in patients and ex vivo
BACKGROUND Cardiovascular-MR (CMR) is the gold standard for quantifying myocardial infarction using late gadolinium enhancement (LGE) technique. Both 2D- and 3D-LGE-sequences are used in clinical practise and in clinical and experimental studies for infarct quantification. Therefore the aim of this study was to investigate if image acquisitions with 2D- and 3D-LGE show the same infarct size in ...
متن کامل