Accuracy of pulse oximeter perfusion index in thoracic epidural anesthesia under basal general anesthesia.

نویسندگان

  • Zifeng Xu
  • Jianhai Zhang
  • Yunfei Xia
  • Xiaoming Deng
چکیده

OBJECTIVE To observe the change of PVI after thoracic epidural block on the basis of general anesthesia. METHODS In 26 patients undergoing elective upper abdominal operations, changes of SVI, PVI, SVV, PPV and CVP were monitored immediately before and 10 minutes after T8-9 thoracic epidural anesthesia on the basis of general anesthesia. The definition was that patients with ΔSVI greater than 10% belonged to response group to epidural block. RESULTS Before epidural block, the PVI, SVV and PPV baseline values in patients of response group were significantly higher than those in patients of non-response group. PVI, SVV and PPV after epidural block were significantly higher than immediately before epidural block (P < 0.001). PVI, SVV and PPV baseline values immediately before epidural block were positively correlated with ΔSVI; the correlation coefficients were 0.70, 0.71 and 0.63, respectively, P ≤ 0.001. The optimal critical values for PVI, SVV and PPV to predict response to T8-9 gap epidural block under general anesthesia were 16% (sensitivity 80%, specificity 92%), 13% (sensitivity 90%, specificity 62%) and 12% (sensitivity 90%, specificity 77%), respectively. CONCLUSION PVI can be used as a noninvasive indictor to monitor volume change after thoracic epidural block on the basis of general anesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Pulse Oximeter Perfusion Index in Pediatric Caudal Block under Basal Ketamine Anesthesia

Whether pulse oximeter perfusion index (PI) may be applied to detect the onset of caudal block in pediatric patients under ketamine intravenous basal anesthesia is investigated. 40 ASA I, 2-8-year-old boys scheduled for elective circumcision surgery were randomized into two groups. Group I: 20 patients were anesthetized by 2 mg·kg(-1) ketamine intravenous injection (IV) followed by caudal block...

متن کامل

Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room.

The frequency and nature of spurious pulse oximetry readings were compared using both a conventional pulse oximeter (CPO) and a prototype Masimo signal extraction technology pulse oximeter (Masimo SET). At a university hospital, 50 ASA physical status I-IV adult patients who underwent general or spinal-epidural anesthesia were selected from a group of 250 patients on the basis of high-alarm gen...

متن کامل

New generation pulse oximetry in the assessment of peripheral perfusion during general anaesthesia - a comparison between propofol and desflurane.

BACKGROUND A pulse oximeter is a standard device for perioperative monitoring. It is well known that the early detection of tissue hypoxia is of great importance. It has been made easier due to a new generation pulse oximetry device from Masimo. This enables measurements of the peripheral perfusion index (PI) in real time. It has been found that volatile anaesthetics such as sevoflurane and des...

متن کامل

Thoracic disc herniation causing transient paraplegia coincident with epidural anesthesia: a case report

Neurological deficits following epidural or spinal anesthesia are extremely rare. Transient paraplegia following epidural anesthesia in a patient with thoracic disc herniation has been presented. A 44-year-old woman developed paraplegia during the operation for vascular surgery of her legs under epidural anesthesia. Epidural hematoma or spinal cord ischemia was ruled out by magnetic resonance i...

متن کامل

Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?

BACKGROUND Respiratory variations in the pulse oximeter plethysmographic waveform amplitude (deltaPOP) are sensitive to changes in preload and can predict fluid responsiveness in mechanically ventilated patients. However, they cannot be easily calculated from a bedside monitor. Pleth variability index (PVI, Masimo Corp., Irvine, CA) is a new algorithm that automatically calculates deltaPOP. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 7 7  شماره 

صفحات  -

تاریخ انتشار 2014