Ultrasound diagnosis of malaria: examination of the spleen, liver, and optic nerve sheath diameter.

نویسندگان

  • Yuanting Zha
  • Michelle Zhou
  • Anjali Hari
  • Bradley Jacobsen
  • Neha Mitragotri
  • Bianca Rivas
  • Olga Gabriela Ventura
  • Janice Boughton
  • John Christian Fox
چکیده

BACKGROUND Over 90% of all cases of malaria worldwide occur in Africa. Current methods of diagnosis are time and labor intensive, and could lead to delayed treatment. METHODS In this study we investigated the effectiveness of measurements of spleen, liver, and optic nerve sheath diameter (ONSD) in identifying patients with malaria or severe malaria through the use of hand-held ultrasound devices. We recruited 40 adult patients with malaria and 16 adult control subjects at two hospitals in Mwanza, Tanzania. Ultrasonographic diagnosis was compared with rapid antigen diagnostic test and peripheral blood smear as the gold standards. An receiver operating characteristic curve test was performed to determine the most optimal diagnostic threshold for malaria and severe malaria, using each of the measurements for liver size, spleen size, and ONSD. The thresholds were determined to be >12 cm for spleen length and >15.1 cm for liver length, whereas ONSD was not significant in this study. RESULTS The sensitivities for malaria diagnosis were 66.7% and 58.3% for liver and spleen length respectively, suggesting that these measurements may not be suitable for identifying patients with severe malaria. However, the high specificity of 90.9% for spleen length and the acceptable specificity of 75.0% for liver length suggest that these measurements can be used as a method to eliminate false-positive diagnoses (i.e. patients who do not have severe malaria but are classified as having it by a test with a high sensitivity), giving a high positive predictive value. CONCLUSIONS We report a high specificity for spleen size and a moderate specificity for liver size in the ultrasonographic diagnosis of severe malaria. Thus when paired with a highly sensitive method of malaria diagnosis, ultrasonographic measurement of spleen and liver size is promising as part of a diagnostic algorithm for malaria. It could be used to stratify risk in patients diagnosed with malaria and assist in their triage. If no sensitive tests are available, ultrasound might be useful to suggest malaria as a cause of a patient's constellation of clinical symptoms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Optic Nerve Sheath Ultrasound for the Bedside Diagnosis of Intracranial Hypertension: Pitfalls and Potential

Raised intracranial pressure is a complication not just of traumatic brain injury and other acute cerebral insults, but also of a number of general medical conditions. Bedside diagnosis can be difficult; early clinical signs may be misinterpreted, and reliance on cross-sectional imaging studies may further delay diagnosis. Ultrasound is a readily available imaging modality in most critical care...

متن کامل

SCIENTIFIC CORRESPONDENCE Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus

Aim: To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure. Methods: 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or c...

متن کامل

Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.

AIM To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure. METHODS 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or c...

متن کامل

Elevated Intracranial Pressure Diagnosis with Emergency Department Bedside Ocular Ultrasound

Bedside sonographic measurement of optic nerve sheath diameter can aid in the diagnosis of elevated intracranial pressure in the emergency department. This case report describes a 21-year-old female presenting with 4 months of mild headache and 2 weeks of recurrent, transient binocular vision loss. Though limited by patient discomfort, fundoscopic examination suggested the presence of blurred o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • World journal of emergency medicine

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2015