Validation of a standardized portable fluorescence method for determining trace beryllium in workplace air and wipe samples.
نویسندگان
چکیده
Beryllium is widely used in industry for its unique properties; however, occupational exposure to beryllium particles can cause potentially fatal disease. Consequently, exposure limits for beryllium particles in air and action levels on surfaces have been established to reduce exposure risks for workers. Field-portable monitoring methods for beryllium are desired in order to facilitate on-site measurement of beryllium in the workplace, so that immediate action can be taken to protect human health. In this work, a standardized, portable fluorescence method for the determination of trace beryllium in workplace samples, i.e., air filters and dust wipes, was validated through intra- and inter-laboratory testing. The procedure entails extraction of beryllium in 1% ammonium bifluoride (NH(4)HF(2), aqueous), followed by fluorescence measurement of the complex formed between beryllium ion and hydroxybenzoquinoline sulfonate (HBQS). The method detection limit was estimated to be less than 0.02 microg Be per air filter or wipe sample, with a dynamic range up to greater than 10 microg. The overall method accuracy was shown to satisfy the accuracy criterion (A< or = +/-25%) for analytical methods promulgated by the US National Institute for Occupational Safety and Health (NIOSH). Interferences from numerous metals tested (in >400-fold excess concentration compared to that of beryllium) were negligible or minimal. The procedure was shown to be effective for the dissolution and quantitative detection of beryllium extracted from refractory beryllium oxide particles. An American Society for Testing and Materials (ASTM) International voluntary consensus standard based on the methodology has recently been published.
منابع مشابه
Development and validation of methods for environmental monitoring of cyclophosphamide in workplaces.
Methods to monitor contamination of workplaces with antineoplastic drugs have been developed and validated. Cyclophosphamide (CP) was used as a model compound as it is one of the most commonly used antineoplastic drugs. A wipe sampling method to detect contamination with CP at surfaces was developed. A personal air sampling method to sample gas and vapour on solid sorbent tubes and particles wi...
متن کاملAssessment of personal airborne exposures and surface contamination from x-ray vaporization of beryllium targets at the National Ignition Facility.
This article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for ...
متن کاملAnalysis of gross alpha, gross beta activities and beryllium- 7 concentrations in surface air: their variation and statistical prediction model
Background: Measurement of gross , gross activities, and cosmogenic beryllium-7 (7Be) concentrations were made both daily and weekly during the years 2001- 2004 from samples of atmospheric aerosols filtered from the air at Tehran Nuclear Research Center (35 41' N) and Zahedan (28 29' N). Materials and Methods: Weekly aerosol samples were collected with the high-volume air samplers on cellul...
متن کاملSelected trace elements evaluation in soil from an urban farming area
BACKGROUND AND OBJECTIVES: Urban farming makes a substantial influence on the household economy of the urban poor especially in developing countries. Urban soil the hot spot of urban farming is a natural sink for contaminants especially the trace elements derived mainly from anthropogenic activities. This study’s aim was to quantify the concentrations of selected trace elements...
متن کاملGross beta activities and Beryllium-7 concentrations in surface air
ABSTRACT Background: were made each week during year 2002 from samples of atmospheric aerosols filtered from theair at Tehran Nuclear Research Center.Measurement of gross beta activities and cosmogenic Beryllium-7 concentrationsMaterials and Methodssampler at the Nuclear Research Center meteorological station in Tehran (40contents of samples were determined with semiconductor gamma spectrometry...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 8 6 شماره
صفحات -
تاریخ انتشار 2006