A novel, versatile valved holding chamber for delivering inhaled medications to neonates and small children: laboratory simulation of delivery options.
نویسندگان
چکیده
BACKGROUND Delivery of bronchodilator to infants and small children from a pressurized metered-dose inhaler with valved holding chamber (pMDI-VHC) is limited by airway narrowness, short respiratory cycle time, and small tidal volume (V(T)). There is a need for a versatile, efficient VHC, given the variety of treatment modalities. METHODS We tested the AeroChamber Mini VHC (the internal geometry of which is optimized for aerosol delivery, and which accepts a pMDI canister that has a dose counter) in experiments to determine differences in the delivery of hydrofluoroalkane-propelled albuterol (90 microg/actuation) during: mechanical ventilation via endotracheal tube (ETT); manual resuscitation via ETT; and spontaneous breathing via face mask. We tested 5 units of the AeroChamber Mini VHC per test. We simulated the tidal breathing of a premature neonate (V(T) 6 mL), a term neonate (V(T) 20 mL), and a child approximately 2 years old (V(T) 60 mL). We collected the aerosol on an electret filter and quantitatively assayed for albuterol. RESULTS The total emitted mass of albuterol per actuation that exited the VHC was marginally greater during spontaneous breathing (12.1 +/- 1.8 microg) than during manual resuscitation (10.0 +/- 1.1 microg) (P = .046). Albuterol delivery via mechanical ventilation, though comparable with the premature-neonate model (3.3 +/- 1.2 microg), the term-neonate model (3.8 +/- 2.1 microg), and the 2-y-old-child model (4.2 +/- 2.3 microg) (P = .63), was significantly lower than in the spontaneous-breathing and manual-resuscitation models (P < .001). In the neonatal models the total emitted mass was similar with the spontaneous-breathing model (6.0 +/- 1.0 microg with the premature-neonate model, 10.5 +/- 0.7 microg with the term-neonate model) and the manual-resuscitation model (5.5 +/- 0.3 microg premature-neonate model, 10.7 +/- 0.9 microg term-neonate model) (P > or = .46 via one-way analysis of variance). CONCLUSION The reduced delivery of albuterol during mechanical ventilation (compared to during spontaneous breathing and manual resuscitation via ETT) was probably associated with the saturated atmosphere in the breathing circuit (37 degrees C, relative humidity > 99%), compared to the ambient air (22 +/- 1 degrees C, 44 +/- 7% relative humidity). The AeroChamber Mini VHC may provide a versatile alternative to VHCs that are designed exclusively for one aerosol treatment modality.
منابع مشابه
AeroChamber ® Valved Holding Chamber (VHC)
INTRODUCTION: Inhaled bronchodilators are one of the most frequently prescribed medications for children hospitalized with respiratory disorders. Historically, the most common method of administration has been via the small-volume nebulizer (SVN). The methods and effectiveness by which these medications are administered to pediatric patients has been evaluated extensively over the last decade. ...
متن کاملThe conversion to metered-dose inhaler with valved holding chamber to administer inhaled albuterol: a pediatric hospital experience.
BACKGROUND Metered-dose inhalers with valved holding chambers (MDI-VHCs) have been shown to be equivalent to small-volume nebulizers (SVNs) for the delivery of bronchodilators in children. At Seattle Children's Hospital and Regional Medical Center we sought to implement the conversion from SVN to MDI-delivered albuterol in nonintubated patients receiving intermittent treatments. METHODS There...
متن کاملThe role of the MDI and DPI in pediatric patients: "Children are not just miniature adults".
Metered-dose inhalers (MDIs) and dry powder inhalers play an important role in the treatment of asthma in children of all ages. Yet these devices, which were originally developed for use in adults, interact differently with children. Through childhood there are progressive changes in pharmacokinetic handling and pharmacodynamic effects of inhaled antiasthmatic drugs, in the efficiency and distr...
متن کاملA metal aerosol holding chamber devised for young children with asthma.
The low tidal volume and flow in preschool children may reduce the efficiency of aerosol delivery from a pressurized metered-dose inhaler (pMDI) through a traditional holding chamber. A prototype small-volume steel holding chamber with two one-way valves was devised to prolong aerosol availability in the chamber and to ensure unidirectional airflow. Dead space between the valves was minimized t...
متن کاملLevalbuterol aerosol delivery with a nonelectrostatic versus a nonconducting valved holding chamber.
BACKGROUND Hydrofluoroalkane-propelled levalbuterol (Xopenex) aerosol is a recently approved formulation for delivery via metered-dose inhaler for the treatment or prevention of bronchospasm in adults, adolescents, and children > or = 4 years of age who have reversible obstructive airway disease. Valved holding chambers (VHCs) made from conventional polymers are susceptible to accumulation of e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 55 4 شماره
صفحات -
تاریخ انتشار 2010