A systematic approach to ultrasound-guided central venous catheter placement—desirable modifications

نویسندگان

  • Ryszard Gawda
  • Tomasz Czarnik
چکیده

With much interest we read the paper written by Saugel et al. [1] on a systemic approach to ultrasound-guided central vein catheterization. The article is comprehensive but some issues need discussing. The authors claim that the tip of the needle can be constantly identified while the needle is approaching the vein both in short-axis and long-axis views. This is inaccurate. The only approach where it is possible to constantly visualize the tip of the needle is the inplane technique. In the short-axis view, the needle is visible as a white dot, which also applies to the tip of the needle as with any part of the needle shaft [2, 3]. It means that the tip can be within the lumen of the vein or below the vessel when the second wall of the vein is punctured. The scheme created by the authors is similar to the one we recently published [4]. Unfortunately, their proposed systematic approach ignores several crucial steps in the procedure. Firstly, the needle is not always visualized perfectly. Therefore, before puncturing the vein, you need to check if the needle has not been positioned over the adjacent artery. How this is done depends on the technique used. It is simple in the short-axis view, when both vessels are constantly presented on the screen, but in the long-axis view, only the vein is visualized; thus, the angle needs to be changed between the ultrasound probe and the skin in order to visualize the adjacent artery. When the tip of the needle is not centrally positioned over the vein, the needle can miss the vein, also damaging the adjacent artery. The other important step is to test the introduction of the guidewire, i.e., to check whether the tip of the guidewire is not being introduced into the other central vein on the same side of the patient. This problem mostly concerns the jugular vein during axillary/subclavian vein catheterization and the axillary/subclavian vein during jugular vein catheterization. This step acts as a protection (but not completely) against introducing the catheter into an undesirable location. In our opinion ultrasound-guided central venous catheter placement is a slightly more complex procedure than the one proposed in the paper. It not only involves introducing the catheter into the vein but also controls all the steps in order to guarantee the safety of the patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time ultrasound detection of correct intravenous placement of central venous catheters after ultrasound cannulation.

Ultrasound-guided technique for central venous catheterization has been a widely developed procedure during the last decade. Nowadays, it is a common technique in the anaesthesiologist’s clinical practice. During the last six years, we usually have carried out central venous catheterization using the ultrasound-guided technique in our hospital. Moreover, we use to check correct intravenous plac...

متن کامل

Ultrasound detection of guidewire position during central venous catheterization.

INTRODUCTION Ultrasound guidance decreases complications of central venous catheter (CVC) placement, but risks of arterial puncture and inadvertent arterial catheter placement exist. Ultrasound-assisted detection of guidewire position in the internal jugular vein could predict correct catheter position before dilation and catheter placement. METHODS Ultrasound examinations were performed in a...

متن کامل

Ultrasound-guided peripheral intravenous access program is associated with a marked reduction in central venous catheter use in noncritically ill emergency department patients.

STUDY OBJECTIVE We examine the central venous catheter placement rate during the implementation of an ultrasound-guided peripheral intravenous access program. METHODS We conducted a time-series analysis of the monthly central venous catheter rate among adult emergency department (ED) patients in an academic urban ED between 2006 and 2011. During this period, emergency medicine residents and E...

متن کامل

Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice

The use of ultrasound (US) has been proposed to reduce the number of complications and to increase the safety and quality of central venous catheter (CVC) placement. In this review, we describe the rationale for the use of US during CVC placement, the basic principles of this technique, and the current evidence and existing guidelines for its use. In addition, we recommend a structured approach...

متن کامل

Ultrasound-guided central venous puncture in an obese patient with cervical adenomegaly.

BACKGROUND AND OBJECTIVES Classical central venous techniques are based on superficial anatomical references and the knowledge of the vascular anatomy of the area to be punctured. The ultrasound allows direct vision of vascular and perivascular structures, and the needle during the procedure. The objective of this report was to describe an ultrasound-guided central venous catheter placement in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2017