Research of Measurement Circuits for High Voltage Current Transformer Based on Rogowski Coils

نویسنده

  • Yan Bing
چکیده

The electronic current transformer plays an irreplaceable position in the field of relay protection and current measurement of the power system. Rogowski coils are used as sensor parts, and in order to improve the measurement accuracy and reliability, the circuits at the high voltage system are introduced and improved in this paper, including the analog integral element, the filtering circuit and the phase shift circuit. Simulations results proved the reliability and accuracy of the improved circuits. Copyright © 2014 IFSA Publishing, S. L.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design Modification of Rogowski Coil for Current Measurement in Low Frequency

The principle object of this paper is to offer a modified design of Rogowski coil based on its frequency response. The improvement of the integrator circuit for nullifying the phase difference between the waveforms of the measured-current and the corresponding terminal voltage is a further object of this investigation. This paper addresses an accurate, yet more efficient measuring and protect...

متن کامل

Rogowski coils theory and experimental results pdf

Number of ingenious experiments to test that their coil was providing. The theory of a Rogowski coil illustrates very well how a coil can be. Provide an elegant experimental demonstration of. rogowski coils suppliers 8 shows.These validate the superior performance of Rogowski coils over conventional. Verified by physical descriptions and experimental results. For comparative purpose, the result...

متن کامل

Nanosecond - Current Probe for High Voltage Experiments

A current probe has been designed which allows measurement of ns;pulsed currents in high voltage environments. The probe consists of a current transformer and an optical transducer. The transformer coil in a metallic torus is considered as a slow-wave transmission line and is terminated with its wave impedance. In this mode of operation current pulses shorter than twice the transit time of the ...

متن کامل

Rogowski coil current transducer compensation method for harmonic active power error

In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90 . In such condition the errors on harmonic power measurement a...

متن کامل

Fault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests

In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014