Gamma Dose Rate Measurements in Kuwait Using a Car-Borne GPS IntegratedDosimetric System

نویسنده

  • Darwish Al-Azmi
چکیده

A mobile system comprising of a Geiger-Muller (GM) dosimeter connected with a smart phone was used for ambient gamma dose rate survey within the districts and on the roads within the state of Kuwait. While the dosimeter provides data on gamma dose rates, the smart phone provides the GPS navigation information and saves the data for subsequent analysis and mapping. The survey covered a total distance of about 2300 km within the country and 3117 data points were recorded to show the dose rate distribution on the map of Kuwait. The results show that the ambient dose rates in Kuwait range from 40 to 180 nSv∙h−1 with a mean value of 103 nSv∙h−1. The dosimetric system described has good potential as a tool for determining baseline background radiation dose rates in an area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rn- 222 Concentration and Gamma Dose Rate Measurements in the Vicinity of Hot Springs in Kerman Province, Southeastern, Iran.

Introduction: Radon-222 gas is a radioactive, colorless and odorless element that can cause lung cancer and stomach in humans with alpha-ray emissions. An important source of Radon-222 is the output water in springs, especially hot springs to emit ionision radiation. In this study, Rn-222 activity concentration and gamma dose rate levels in water sample of some selected hot spr...

متن کامل

Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters

Background and Objective: Human external exposure to natural radiation sources is much more than artificial radiation sources. In this study, external annual effective doses were estimated in cities of Gorgan and Bandar-Torkman by determining ambient gamma dose rate in indoor and outdoor spaces. Materials and Methods: Using an ionization chamber detector, the outdoor and indoor ambient gamma d...

متن کامل

Natural Gamma Radiation in Primary Schools of Zanjan Province

Background: Environmental gamma ray refers to the gamma radiation from terrestrial sources and building materials. In enclosed spaces radiation can become a health hazard leading to potential increase in the rates of lung cancer. The goal of this study is to assess the exposure to natural gamma radiation of children in the schools of Zanjan province. Method:The natural gamma radiation was asse...

متن کامل

بررسی آهنگ دوز گامای محیطی در شهرهای اردبیل و سرعین در سال 1387

Background and Objectives: Gamma rays, the most energetic photons within the any other wave in the electromagnetic spectrum, pose enough energy to form charged particles and adversely affect human health. Provided that the external exposure of human beings to natural environmental gamma radiation normally exceeds that from all man-made sources combined, environmental gamma dose rate and corresp...

متن کامل

The use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique

Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014