The application of extended modified Lambert Beer model for measurement of blood carboxyhemoglobin and oxyhemoglobin saturation
نویسندگان
چکیده
This work presents the use of extended Modi ̄ed Lambert Beer (MLB) model for accurate and continuous monitoring of percent blood carboxyhemoglobin (COHb) (SCO) and oxyhemoglobin (OxyHb) saturation (SO2) via a ̄tting procedure. This quanti ̄cation technique is based on the absorption characteristics of hemoglobin derivatives in the wavelength range of 520–600 nm to give the best estimates of the required parameters. A comparison of the performance of the developed model and MLB law is made using attenuation data from Monte Carlo simulations for a two-layered skin model. The results revealed a lower mean absolute error of 0:4% in the values estimated by the developed model as compared to 10% that is given by the MLB law. This study showed that the discussed approach is able to provide consistent and accurate measurement of blood SO2 and SCO across di®erent skin pigmentations suggesting that it may potentially be used as an alternative means for clinical diagnosis of carbon monoxide (CO) poisoning.
منابع مشابه
Dynamic hyperinflation, intrinsic positive end-expiratory pressure, and respiratory rate.
In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...
متن کاملMethemoglobinemia and Pulse Oximetry
In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...
متن کاملPulse Oximetry in Acute Respiratory Failure: What Should Be Expected?-Reply.
To the Editor: In the April issue of RESPIRATORY CARE, Amalakanti and Pentakota1 present a comparison of arterial oxygen saturation values between a 2-wavelength pulse oximeter and blood gas multi-wavelength hemoximetry in COPD subjects with acute respiratory failure. The authors conclude that the 2-wavelength pulse oximeter significantly overestimates arterial oxygen saturation and that COPD a...
متن کاملNon-invasive Estimation of Blood Oxyhemoglobin and Carboxyhemoglobin Saturations Using Cumulant Based Forward Model
This paper aims to study the feasibility of using optical reflectance spectroscopy and Cumulant based forward model (CM) for non-invasive investigation of differences in mean blood oxyhemoglobin (SmO2) and carboxyhemoglobin saturations (SmCO) amongst the participated smoking and nonsmoking recruits, and the effects of different smoking characteristics of smokers on the predicted SmCO level. The...
متن کاملAbsorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin.
We determined the millimolar absorptivities of the four clinically relevant derivatives of fetal and adult human hemoglobin in the visible and near-infrared spectral range (450-1000 nm). As expected, spectral absorption curves of similar shape were found, but the small differences between fetal and adult hemoglobin absorptivity were important enough that they should be taken into account in mul...
متن کامل