The normal blood clotting time in the light of experience with the two-syringe technique.
نویسنده
چکیده
The surgeon who requests the pathological laboratory to determine a patient's blood clotting time expects a result which will indicate if surgery might be dangerous. If he follows the teaching of Cummine and Lyons (1948) or of Dutton (1954) he may wish to use the test to anticipate thromboembolic episodes. The physician may request the test for various reasons. It is, accordingly, very important to know the upper limit of normal, which is stated by Wintrobe (1951) to be 15 minutes using the method of Lee and White (1913). Other textbooks give lower figures. Friedman, Schwartz, and Vincenti (1952), using a two-tube Lee-and-White technique, made the range of normal 7 to 25 minutes. They regarded the test as affording "little if any useful function in evaluating the clotting mechanism, especially in relation to the bleeding and clotting tendencies." The work of Allen and Attyah (1953) suggested a possible explanation of these inconsistencies. These workers claimed that, even when a vein was entered with minimal trauma, blood withdrawn into the first syringe clotted sooner than that withdrawn subsequently into a second syringe. Normal medical students were used in their investigations. With large-calibre short tubes (internal diameter 9.5 mm., height 40 mm.) and 10 ml. syringes with 20-gauge needles, they showed that the coagulation time of the blood in the second syringe was significantly longer than that in the first. Each of 10 tubes was filled from the bottom with 1 ml. using an 18-gauge needle, and the whole test was performed in a water-bath at 370 C. The end-point was taken at the time for the blood in the last tube to clot, each being completely inverted at intervals of five minutes. The tubes were examined in the order in which they had been filled. In 96% the clotting time was 2035 minutes; it was never under 15 or over 40 and the average was 26 minutes. Method of Investigation
منابع مشابه
Nano-structure TiO2 film coating on 316L stainless steel via sol-gel technique for blood compatibility improvement
Objective(s): Titanium oxides are known to be appropriate hemocompatible materials which are suggested as coatings for blood-contacting devices. Little is known about the influence of nanometric crystal structure, layer thickness, and semiconducting characteristics of TiO2 on blood hemostasis. Materials and Methods: Having used sol-gel dip coating method in this study, TiO2 thin films were d...
متن کاملStudy of Blood Parasites of the Three Snake Species in Iran: Natrix natrix, Natrix tessellata and Zamenis longissimus (Colubridae)
Infections with blood parasites are common phenomenon in reptiles from all over the world. Apicomplexan are the majority of blood parasites that frequently occur with high levels of parasitaemia in the snakes. The aim of this study was to determine the presence of blood parasites in some snakes Guilan province in the North of Iran. A total of 51 specimens of three snake species were captured in...
متن کاملEvaluation of Normal Range of Bleeding Scores in Healthy Iranian Adults using the International Society on Thrombosis and Hemostasis Bleeding Assessment Tool
Background: Bleeding assessment tools are key components in the evaluation of patients suspicious for bleeding disorders. The exact determination of the normal ranges of ISTH-BAT (International Society on Thrombosis and Hemostasis –Bleeding Assessment Tool) in the healthy population is a crucial step for determining who needs to be referred for further coagulation laboratory examinations. We ai...
متن کاملBand Structures for 2D Photonic Crystals in Presence of Nonlinear Kerr Effect Calculated by Use of Nonlinear Finite Difference Time Domain (NFDTD) Method
We report the simulation results for impact of nonlinear Kerr effect on band structures of a two dimensional photonic crystal (2D-PhC) with no defect, a PhC based W1-waveguide (W1W), and also Coupled-Cavity Waveguides (CCWs). All PhC structres are assumed to a square lattice of constant a made of GaAs rods of radius r=0.2a, in an air background. The numerical simulation was performed using...
متن کاملApplication of near-infrared light intensity to determine normal and cancerous breast vessel contrast by gold nanoparticles
Objective(s): A novel technique for the early diagnosis of breast cancer involves the use of nanoparticles (NPs). The present study aimed to use gold NPs to assess the variations in light source transfer intensity. Materials and Methods: Blood samples with hemoglobin (Hb) concentrations of ×1, ×2, and ×4 were used to simulate normal and cancerous conditions in the breast. Spherical gold N...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 8 3 شماره
صفحات -
تاریخ انتشار 1955