Glucose production during an IVGTT by deconvolution: validation with the tracer-to-tracee clamp technique.

نویسندگان

  • Paolo Vicini
  • Jeffrey J Zachwieja
  • Kevin E Yarasheski
  • Dennis M Bier
  • Andrea Caumo
  • Claudio Cobelli
چکیده

Recently, a new method, based on a two-compartment minimal model and deconvolution [A. Caumo and C. Cobelli. Am. J. Physiol 264 ( Endocrinol. Metab.. 37): E829-E841, 1993; P. Vicini, G. Sparacino, A. Caumo, and C. Cobelli. Comput. Meth. Prog. Biomed. 52: 147-156, 1997], has been proposed to estimate endogenous glucose production (EGP) from labeled intravenous glucose tolerance test (IVGTT) data. Our aim here is to compare this EGP profile with that independently obtained with the reference method, based on the tracer-to-tracee ratio (TTR) clamp. An insulin-modified (0.03 U/kg body wt infused over 5 min) [6,6-2H2]glucose-labeled IVGTT (0.33 g/kg of glucose) was performed in 10 normal subjects. A second tracer ([U-13C]glucose) was also infused during the test in a variable fashion to clamp endogenous glucose TTR. The TTR clamp was quite successful. As a result, the EGP profile, reconstructed from [U-13C]glucose data with the models of Steele and Radziuk, were almost superimposable. The deconvolution-obtained EGP profile, calculated from [6,6-2H2]glucose data, showed remarkable agreement with that obtained from the TTR clamp. Some differences between the two profiles were noted in the estimated basal EGP and in the initial modalities of EGP inhibition. A high interindividual variability was also observed with both methods in the resumption of EGP to baseline; variability was high in both the timing and the extent of resumption. In conclusion, the use of the two-compartment minimal model of the IVGTT and deconvolution allows the estimation of a profile of EGP that is in very good agreement with that independently obtained with a TTR clamp.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of selective effect of insulin on glucose disposal from labeled glucose oral test minimal model.

The oral glucose minimal model (OMM) measures insulin sensitivity (S(I)) and the glucose rate of appearance (R(a)) of ingested glucose in the presence of physiological changes of insulin and glucose concentrations. However, S(I) of OMM measures the overall effect of insulin on glucose utilization and glucose production. In this study we show that, by adding a tracer to the oral dose, e.g., of a...

متن کامل

Integrated model of hepatic and peripheral glucose regulation for estimation of endogenous glucose production during the hot IVGTT.

We have developed a new model to describe endogenous glucose kinetics during a labeled (hot) intravenous glucose tolerance test (IVGTT) to derive a time profile of endogenous glucose production (EGP). We reanalyzed data from a previously published study (P. Vicini, J. J. Zachwieja, K. E. Yarasheski, D. M. Bier, A. Caumo, and C. Cobelli. Am J Physiol Endocrinol Metab 276: E285-E294, 1999), in wh...

متن کامل

13C- and 2H-labelled glucose compared for minimal model estimates of glucose metabolism in man.

In the present study, we have investigated the use of 1-[(13)C]glucose and GC/combustion/isotope-ratio MS as an alternative to 6,6-[(2)H(2)]glucose and GC/MS in the determination of parameters of glucose metabolism using the IVGTT (intravenous glucose tolerance test) interpreted by labelled (hot) minimal models. The study has been done in four populations, normoglycaemics (subdivided into lean ...

متن کامل

Modeling hepatic insulin sensitivity during a meal: validation against the euglycemic hyperinsulinemic clamp.

Recently, we proposed a model describing the suppression of endogenous glucose production (EGP) during a meal. It assumes that EGP suppression depends on glucose concentration and its rate of change and on delayed insulin action. Hepatic insulin sensitivity (S(I)(Lmeal)) can be derived from EGP model parameters. This model was shown to adequately describe EGP profiles measured with multiple tra...

متن کامل

Minimal model estimation of glucose absorption and insulin sensitivity from oral test: validation with a tracer method.

Measuring insulin sensitivity during the physiological milieu of oral glucose perturbation, e.g., a meal or an oral glucose tolerance test, would be extremely valuable but difficult since the rate of appearance of absorbed glucose is unknown. The reference method is a tracer two-step one: first, the rate of appearance of glucose (R(a meal)(ref)) is reconstructed by employing the tracer-to-trace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Endocrinology and metabolism

دوره 276 2  شماره 

صفحات  -

تاریخ انتشار 1999