Input impedance and peripheral inhomogeneity of dog lungs.

نویسندگان

  • Z Hantos
  • B Daróczy
  • B Suki
  • S Nagy
  • J J Fredberg
چکیده

Tracheal pressure, central airflow, and alveolar capsule pressures in cardiac lobes were measured in open-chest dogs during 0.1- to 20-Hz pseudorandom forced oscillations applied at the airway opening. In the interval 0.1-4.15 Hz, the input impedance data were fitted by four-parameter models including frequency-independent airway resistance and inertance and tissue parts featuring a marked negative frequency dependence of resistance and a slight elevation of elastance with frequency. The models gave good fits both in the control state and during histamine infusion. At the same time, the regional transfer impedances (alveolar pressure-to-central airflow ratios) showed intralobar and interlobar variabilities of similar degrees, which increased with frequency and were exaggerated during histamine infusion. Results of simulation studies based on a lung model consisting of a central airway and a number of peripheral units with airway and tissue parameters that were given independent wide distributions were in agreement with the experimental findings and showed that even an extremely inhomogeneous lung structure can produce virtually homogeneous mechanical behavior at the input.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary Bulla in a Dog Secondary to Blastomycosis

Case description- A two-year-old intact Golden Retriever was affected with the 6-months previous history of blastomycosis and treatment was performed using fluconazole. Clinical findings- Cough, fever, nasal discharge, dry and harsh lung sounds with peripheral lymphadenopathy was observed. Emphysematous change and large pulmonary bulla was reported in computed tomography of the thorax. Treatm...

متن کامل

Effects of Afterload Reduction

We examined the effects of graded reduction of afterload on the global left ventricular and regional myocardial functions as well as coronary hemodynamics in hearts with regional ischemia. We used isolated, paced canine hearts that were loaded with a hydraulic system that simulated the aortic input impedance of the dog's arterial tree. The loading conditions could be quantitatively and sequenti...

متن کامل

Ventilation inhomogeneity is one criterion among many in multidimensional PEEP titration

Amato [1] on our recent study [2], in which we proposed that ventilation inhomogeneity should be regarded as an additional prospective index along with blood gases, lung mechanics and hemodynamics in a multifactorial method to optimize positive end-expiratory pressure (PEEP) at the bedside. We agree with Costa and Amato that some ventilation heterogeneity may be good [1]. Especially in patients...

متن کامل

A simple form of MT impedance tensor analysis to simplify its decomposition to remove the effects of near surface small-scale 3-D conductivity structures

Magnetotelluric (MT) is a natural electromagnetic (EM) technique which is used for geothermal, petroleum, geotechnical, groundwater and mineral exploration. MT is also routinely used for mapping of deep subsurface structures. In this method, the measured regional complex impedance tensor (Z) is substantially distorted by any topographical feature or small-scale near-surface, three-dimensional (...

متن کامل

Analysis of Strain Inhomogeneity in Vortex Extrusion using Finite Element Method and Response Surface Methodology

The effect of geometrical parameters involved in vortex extrusion (VE) die design, on AA1050 aluminium alloy processed by VE were investigated using finite element analysis (FEA) and response surface methodology (RSM). For this, VE die length (L), reduction in area (RA), twist angle , and position of control points in Beziers' formulation (C1) were considered as input parameters and strain inho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 72 1  شماره 

صفحات  -

تاریخ انتشار 1992