Resistive polymer versus forced-air warming: comparable heat transfer and core rewarming rates in volunteers.

نویسندگان

  • Oliver Kimberger
  • Christine Held
  • Karin Stadelmann
  • Nikolaus Mayer
  • Corinne Hunkeler
  • Daniel I Sessler
  • Andrea Kurz
چکیده

BACKGROUND Mild perioperative hypothermia increases the risk of several severe complications. Perioperative patient warming to preserve normothermia has thus become routine, with forced-air warming being used most often. In previous studies, various resistive warming systems have shown mixed results in comparison with forced-air. Recently, a polymer-based resistive patient warming system has been developed. We compared the efficacy of a standard forced-air warming system with the resistive polymer system in volunteers. METHODS Eight healthy volunteers participated, each on two separate study days. Unanesthetized volunteers were cooled to a core temperature (tympanic membrane) of 34 degrees C by application of forced-air at 10 degrees C and a circulating-water mattress at 4 degrees C. Meperidine and buspirone were administered to prevent shivering. In a randomly designated order, volunteers were then rewarmed (until their core temperatures reached 36 degrees C) with one of the following active warming systems: (1) forced-air warming (Bair Hugger warming cover #300, blower #750, Arizant, Eden Prairie, MN); or (2) polymer fiber resistive warming (HotDog whole body blanket, HotDog standard controller, Augustine Biomedical, Eden Prairie, MN). The alternate system was used on the second study day. Metabolic heat production, cutaneous heat loss, and core temperature were measured. RESULTS Metabolic heat production and cutaneous heat loss were similar with each system. After a 30-min delay, core temperature increased nearly linearly by 0.98 (95% confidence interval 0.91-1.04) degrees C/h with forced-air and by 0.92 (0.85-1.00) degrees C/h with resistive heating (P = 0.4). CONCLUSIONS Heating efficacy and core rewarming rates were similar with full-body forced-air and full-body resistive polymer heating in healthy volunteers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra-operative rewarming with Hot Dog(®) resistive heating and forced-air heating: a trial of lower-body warming.

Resistive heating is an alternative to forced-air warming which is currently the most commonly used intra-operative warming system. We therefore tested the hypothesis that rewarming rates are similar with Hot Dog(®) (Augustine Biomedical) resistive and Bair Hugger(®) (Arizant) forced-air heating systems. We evaluated 28 patients having major maxillary tumour surgery. During the establishment of...

متن کامل

Effects of a circulating-water garment and forced-air warming on body heat content and core temperature.

BACKGROUND Forced-air warming is sometimes unable to maintain perioperative normothermia. Therefore, the authors compared heat transfer, regional heat distribution, and core rewarming of forced-air warming with a novel circulating-water garment. METHODS Nine volunteers were each evaluated on two randomly ordered study days. They were anesthetized and cooled to a core temperature near 34 degre...

متن کامل

Negative pressure rewarming vs. forced air warming in hypothermic postanesthetic volunteers.

We compared changes in core temperature and systemic heat balance with a new negative pressure/warming device (Vital Heat(R) ) that uses negative pressure combined with heat to facilitate warming in vasoconstricted postoperative patients to those resulting from passive insulation or forced air. Seven healthy volunteers were anesthetized and cooled to a tympanic membrane temperature near 34 degr...

متن کامل

Comparison of forced-air warming and resistive heating.

BACKGROUND Perioperative hypothermia is common during anesthesia and surgery and is accompanied by several complications. Forced-air warming is recognized as an effective procedure to prevent hypothermia. The aim of this study was to compare a resistive heating device with a forced-air warming device. METHODS Prospective randomized trial. SETTING heat transfer laboratory of a University hos...

متن کامل

Resistive-polymer versus forced-air warming: comparable efficacy in orthopedic patients.

BACKGROUND Several adverse consequences are caused by mild perioperative hypothermia. Maintaining normothermia with patient warming systems, today mostly with forced air (FA), has thus become a standard procedure during anesthesia. Recently, a polymer-based resistive patient warming system was developed. We compared the efficacy of a widely distributed FA system with the resistive-polymer (RP) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 107 5  شماره 

صفحات  -

تاریخ انتشار 2008