Relation between maximum time-varying elastance pressure-volume areas and myocardial oxygen consumption in dogs.
نویسندگان
چکیده
To establish whether pressure-volume areas (PVAs) calculated using the maximum time-varying elastance (Emax) have a relation with myocardial oxygen consumption (MVO2) that improves on other indexes of myocardial oxygen demand, we studied nine dogs of either sex weighing 19-39 kg, which were instrumented with a micromanometer left ventricular (LV) catheter and a Wilton-Webster coronary sinus flow catheter and had red blood cells tagged with technetium-99m for radionuclide angiography. Hemodynamics, coronary sinus flow determinations, and radionuclide angiograms were obtained under control conditions and during three to five steady-state loading conditions (mean +/- SD, 5.6 +/- 0.7). Isochronal pressure-volume data points from each pressure-volume loop were subjected to linear regression analysis to calculate Emax. The Emax relations, diastolic curves, and systolic portions of each pressure-volume loop were used to obtain calibrated PVAs. The Emax PVA (mm Hg.ml.beat-1.100 g-1) and MVO2 (ml O2.beat-1.100 g-1) values correlated in each animal (r = 0.77 to 0.99). Their slopes averaged (3.48 +/- 1.68) x 10(-5) ml O2.mm Hg-1.ml-1, and their y-axis intercepts averaged 0.07 +/- 0.04 ml O2.beat-1.100 g-1. When the MVO2 relations were compared with Emax PVA, LV systolic pressure-rate product, LV stroke work, and a modification of the LV pressure-work index, the Emax PVA, LV systolic pressure-rate product, and LV pressure-work index had similar relations with MVO2, whereas LV stroke work was a weaker index of MVO2 (p less than 0.05 versus Emax PVA). This occurred because the Emax PVA:MVO2 slopes and y-axis intercepts differed in each dog, which was due to differences in basal LV contractility. The Emax PVA:MVO2 slopes correlated with Emax (r = 0.73, p less than 0.05), and the y-axis intercepts were also weakly related to Emax (r = 0.48, p = 0.19). We conclude that the Emax PVAs calculated using data acquisition techniques that are clinically applicable have relations with MVO2 that in general do not improve on other indexes of myocardial oxygen demand in this animal preparation.
منابع مشابه
Time-invariant oxygen cost of mechanical energy in dog left ventricle: consistency and inconsistency of time-varying elastance model with myocardial energetics.
We studied whether the oxygen cost of mechanical energy is time-invariant in the excised, cross-circulated canine heart. The total mechanical energy generated by ventricular contraction can be quantified by the total pressure-volume area (PVA) according to the time-varying elastance model. In this model, mechanical energy generated until a specified time (t) during systole can be quantified by ...
متن کاملLeft ventricular function: time-varying elastance and left ventricular aortic coupling
Many aspects of left ventricular function are explained by considering ventricular pressure-volume characteristics. Contractility is best measured by the slope, Emax, of the end-systolic pressure-volume relationship. Ventricular systole is usefully characterized by a time-varying elastance (ΔP/ΔV). An extended area, the pressure-volume area, subtended by the ventricular pressure-volume loop (us...
متن کاملCorrelation of force-length area with oxygen consumption in ferret papillary muscle.
The ventricular systolic pressure-volume area correlates well with myocardial oxygen consumption. However, in isolated muscle preparations, there are experimental data based on both mechanical and energetic measurements that suggest that the pressure-volume area concept may not obtain. In the present study, force-length area, the analog of pressure-volume area for a linear muscle, was examined ...
متن کاملThe left ventricular dP/dtmax-end-diastolic volume relation in closed-chest dogs.
I investigated the relation of the maximum rate of left ventricular pressure rise to the end-diastolic volume and the comparison of the maximum rate of left ventricular pressure rise-end-diastolic volume relation to the end-systolic pressure-volume relation, using the time-varying elastance model. These studies were performed in 11 dogs chronically instrumented to measure left ventricular press...
متن کاملLeft ventricular time varying elastance behavior does not reflect a basic property of cardiac muscle.
The article of Hisano and Cooper raises once again the seemingly unresolved question on the myocardial basis for the time varying elastance behavior of the left ventricle, a concept formalized by Suga et al in 1973. From their experiments, Hisano and Cooper conclude that "the correlation of pressurevolume area with oxygen consumption on the ventricular level arises from a basic property of card...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 83 1 شماره
صفحات -
تاریخ انتشار 1991