3DQRS: a method to obtain reliable QRS complex detection within high field MRI using 12-lead electrocardiogram traces.

نویسندگان

  • T Stan Gregory
  • Ehud J Schmidt
  • Shelley Hualei Zhang
  • Zion Tsz Ho Tse
چکیده

PURPOSE To develop a technique that accurately detects the QRS complex in 1.5 Tesla (T), 3T, and 7T MRI scanners. METHODS During early systole, blood is rapidly ejected into the aortic arch, traveling perpendicular to the MRI's main field, which produces a strong voltage (V(MHD)) that eclipses the QRS complex. Greater complexity arises in arrhythmia patients, since V(MHD) varies between sinus-rhythm and arrhythmic beats. The 3DQRS method uses a kernel consisting of 6 electrocardiogram (ECG) precordial leads (V1-V6), compiled from a 12-lead ECG performed outside the magnet. The kernel is cross-correlated with signals acquired inside the MRI to identify the QRS complex in real time. The 3DQRS method was evaluated against a vectorcardiogram (VCG)-based approach in two premature ventricular contraction (PVC) and two atrial fibrillation (AF) patients, a healthy exercising athlete, and eight healthy volunteers, within 1.5T and 3T MRIs, using a prototype MRI-conditional 12-lead ECG system. Two volunteers were recorded at 7T using a Holter recorder. RESULTS For QRS complex detection, 3DQRS subject-averaged sensitivity levels, relative to VCG were: 1.5T (100% versus 96.7%), 3T (98.9% versus 92.2%), and 7T (96.2% versus 77.7%). CONCLUSION The 3DQRS method was shown to be more effective in cardiac gating than a conventional VCG-based method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing 3DQRS and VCG approaches for ECG QRS detection within 1.5T, 3T and 7T MRI

Background Electrocardiograms (ECGs) obtained within High-field MRIs are distorted due to the Magneto-hydrodynamic (MHD) effect. Blood plasma electrolytes ejected into the aorta during early systole interact with the strong magnetic field of the MR scanner to produce a MHD-induced voltage (VMHD) [1]. The VMHD overlay on ECG traces can result in intermittent QRS detection. Vectorcardiogram (VCG)...

متن کامل

Improved cardiac gating at 3T with the “3D-QRS” method utilizing MRI-compatible 12-lead ECGs

Background Blood is rapidly ejected from the left ventricle during early systole, travels in the aortic arch perpendicular to the MRI’s main field, thus generating a Magnetohydrodynamic (MHD) voltage which is larger than the real ECG QRS complex in high field MRI. The MHD voltage (VMHD) is severally irregular in patients with arrhythmia, since arrhythmic ECG beats are interleaved between succes...

متن کامل

ECG Electrode Placements for Magnetohydrodynamic Voltage Suppression and improving Cardiac Gating in high-field MRI

Background The accuracy of Electrocardiogram (ECG) gating for synchronization of MR scanner image acquisition and cardiac electrical activity is of great importance for acquiring high-quality Cardiac Magnetic Resonance (CMR) images free of motion artefacts. The distortion of ECG traces by Magnetohydrodynamic Voltages (VMHD) induced by interaction between the MRI static magnetic field (B0) and r...

متن کامل

Correlation between QRS Complex Changes and Cardiac Iron Overload in Beta Thalassemia Major Patients Using T2*MRI

Background and purpose: Cardiac magnetic resonance imaging (MRI) is a costly method to assess cardiac iron overload. The presence of fragmented QRS (fQRS) indicates changes due to iron overload in cardiac tissue. The aim of this study was to evaluate the correlation between fQRS and cardiac iron overload using cardiac MRI in patients with β-thalassemia major (β-TM). Materials and methods: This...

متن کامل

A Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure

In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 71 4  شماره 

صفحات  -

تاریخ انتشار 2014