Screening INR deviation of local prothrombin time systems.
نویسنده
چکیده
AIM To assess the reliability of local international normalised ratios (INR) using a set of three international reference preparation (IRP) certified freeze dried plasmas. METHODS 55 centres in the United Kingdom and the Republic of Ireland participated; 36 centres employed coagulometers and 19 a manual prothrombin time technique, all with the same batch of routine commercial thromboplastin. The plasmas had certified INR with the manual technique using a thromboplastin IRP, and results were provided graphically to participants for self assessment. An INR deviation of more than +/- 10% from the certified INR with any of the screening plasmas was regarded as unsatisfactory and clinically significant. Sets of 20 freeze dried plasmas were provided for local ISI calibrations and sets of seven freeze dried normals were provided for supplementary exercises where screening results were unsatisfactory. RESULTS 15 of 38 coagulometers, but only three of the 19 manual prothrombin time test techniques, gave unsatisfactory results. With 10 of the 15 unsatisfactory coagulometer results the problem was resolved by local ISI calibrations with plasma calibrant sets provided. Unsatisfactory results with manual technique in all four instances were corrected by substitution of the mean result with freeze dried normal plasmas provided. CONCLUSIONS The freeze dried plasma screening set was useful in detecting incorrect INR in a high proportion of coagulometer users and a smaller number of participants using the manual technique.
منابع مشابه
Simplified method for international normalized ratio (INR) derivation based on the prothrombin time/INR line: an international study.
BACKGROUND The need to perform local International Sensitivity Index (ISI) calibrations and in particular the requirement for a manual method for prothrombin time (PT) determination, have proved to be obstacles to application of the WHO scheme for PT standardization. METHODS We used international normalized ratio (INR) derived with a set of only 5 European Concerted Action on Anticoagulation ...
متن کاملEffect of automation on prothrombin time test in NEQAS surveys.
The performance of coagulometers in the National Quality Assessment Scheme (NEQAS) surveys of the prothrombin time conducted between 1986 and 1987 was reviewed. There were sufficient data for analysis for eight types of coagulometer used with a single type of thromboplastin reagent and one instrument with an alternative reagent. The overall reliability efficacy of each instrument was evaluated ...
متن کاملCoaguChek point-of-care testing prothrombin time monitors.
A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by e...
متن کاملComparison between Prothrombin Complex Concentrate (PCC) and Fresh Frozen Plasma (FFP) for the Urgent Reversal of Warfarin in Patients with Mechanical Heart Valves in a Tertiary Care Cardiac Center
Fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC) reverse oral anticoagulants such as Warfarin. We compared the standard dosage FFP and PCC in terms of efficacy and safety for patients with mechanical heart valves undergoing interventional procedures while receiving Warfarin. Fifty patients were randomized (25 for each group) with mechanical heart valves [international normali...
متن کاملComparison between Prothrombin Complex Concentrate (PCC) and Fresh Frozen Plasma (FFP) for the Urgent Reversal of Warfarin in Patients with Mechanical Heart Valves in a Tertiary Care Cardiac Center
Fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC) reverse oral anticoagulants such as Warfarin. We compared the standard dosage FFP and PCC in terms of efficacy and safety for patients with mechanical heart valves undergoing interventional procedures while receiving Warfarin. Fifty patients were randomized (25 for each group) with mechanical heart valves [international normali...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 51 5 شماره
صفحات -
تاریخ انتشار 1998