Current Concepts Review Wear in Total Hip and Knee Replacements
نویسنده
چکیده
Before the advent of total joint replacement, patients who had end-stage arthritis of the lower extremities had unremitting pain and a greatly decreased functional capacity. In addition, they often were confined to a wheelchair and were dependent on the care of others. Today, the outcomes of primary total hip and knee replacement are predictable and usually excellent. Prosthetic joint replacement has dramatically improved the lives of millions of people worldwide. As the fixation of total joint implants has become more reliable and durable and as the technology of total joint replacement has been applied to younger and more active patients, the current limitations of total joint arthroplasty are related to the wear of the components. Wear is the removal of material, with the generation of wear particles, that occurs as a result of the relative motion between two opposing surfaces under load. In complex mechanical-biological systems such as total hip and knee replacements, there can be many types of wear. Although the mechanical consequences of wear, such as progressive thinning of polyethylene components, can limit the functional life of a joint replacement, the clinical problems from wear more frequently are due to the release of an excessive number of wear particles into a biological environment. When particles within a certain size-range are phagocytized in sufficient amounts, the macrophages enter into an activated state of metabolism, releasing substances that can result in periprosthetic bone resorption. Progressive loss of periprosthetic bone can necessitate a reoperation, which is the definitive measure of clinical failure of a joint arthroplasty.
منابع مشابه
Current state and future of joint replacements in the hip and knee.
Joint replacements of the hip and knee are among the most clinically successful operations. According to figures compiled by the American Academy of Orthopaedic Surgeons, the number of primary total hip replacements performed in the USA was 220,000 in 2003. This was 38% more than in 1996 and this number is expected to rise to 572,000 (plus another 97,000 revisions) by 2030. The number of primar...
متن کاملInvestigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation
The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...
متن کاملWear of ceramic-on-carbon fibre reinforced PEEK hip replacements
Total hip replacement has been a successful surgical intervention for many years. However, concerns regarding UHMWPE wear particle induced osteolysis [1], have led to alternative bearing materials to be sought. Carbon-fibre reinforced poly-ether-ether-ketone (CFR-PEEK) is a fibre-reinforced polymer which has shown reduced wear in hip and knee configurations compared with conventional polyethyle...
متن کاملA comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements
A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and...
متن کاملWear Properties of UHMWPE in CHARITE َ Artificial Inter-vertebral Disc
Over the past three decades more than a half a million joint replacements have been performed. Several advances have been made to the design of the implants, but despite the large success of these procedures, loosening of the components and periprosthetic osteolysys often requires a revision surgery. In looking at what causes this, the wear of the UHMWPE articulation surface and the associated ...
متن کامل