Products identified at an alternative disinfection pilot plant.

نویسندگان

  • B W Lykins
  • W Koffskey
چکیده

Many drinking water utilities have recently changed or are seriously considering changing their disinfection practice from chlorine to some alternative treatment process. However, most of these utilities are changing their disinfectants without evaluating chemical impacts. Therefore, a research cooperative agreement was developed with Jefferson Parish, LA, to evaluate four parallel streams treated with four different disinfectants (chlorine, monochloramine, chlorine dioxide, and ozone.) These streams, along with a fifth parallel stream, which was not treated with a disinfectant (control), were passed through both sand and granular activated carbon (GAC). Ozonation reduced the total organic carbon (TOC) and total organic halide (TOX) concentration by 0.3 mg/L and 10 micrograms/L, respectively. The average concentration of TOC for the other disinfectants was comparable to that associated with the nondisinfected stream (3.3 mg/L). The average instantaneous TOX concentration for chlorine dioxide, chloramine, and chlorine disinfection after 30 min contact time increased by 60, 92, and 238 micrograms/L, respectively, from a nondisinfected concentration of 25 micrograms/L. The volatile organics most affected by disinfection (chlorination) were the trihalomethanes. No significant change in concentration was noted after disinfection for the other volatile organics evaluated, such as 1,2-dichlorethane, dichloromethane, trichloroethylene, 1,1,2-trichloroethane, and carbon tetrachloride. Ozonation produced an average concentration reduction of 11 to 84% for most of the nonvolatiles evaluated. Conversely, a concentration increase of 43 to 100% was noted, after chlorination, for some of the nonvolatile organics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pilot Plant Investigation of Ozone Disinfection of Physico- Chemically Treated Municipal Wastewater

An ozonation pilot plant was installed at the Montréal Urban Community Wastewater Treatment Plant (MUCWTP) to assess the feasibility of employing a full scale ozone disinfection system. Wastewater characteristics such as turbidity, COD, TOC, BOD, pH, ORP and suspended solids were monitored to assess their effect on ozone disinfection. Fecal conforms (FC) were used as indicators to measure disin...

متن کامل

Simultaneous control of microorganisms and disinfection by-products by sequential chlorination.

OBJECTIVE To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. METHODS Pilot tests of this sequential chlorination were carried out in a drinking water plant. RESULTS The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the...

متن کامل

Biodesulfurization of Tabas Coal in Pilot Plant Scale

Sulfur emission from coal combustion presents many environmental problems. The techniques used to reduce the amount of sulfur in coal before combustion, include physical, chemical and biological processes.Biological processes based on degradation of sulfur compounds by microorganisms offer many advantages over the conventional physical and chemical processes. The processes are performed und...

متن کامل

Mutagenic activity associated with by-products of drinking water disinfection by chlorine, chlorine dioxide, ozone and UV-irradiation.

A retrospective epidemiological study in The Netherlands showed a statistical association between chlorination by-products in drinking water and cancer of the esophagus and stomach for males. A pilot-plant study with alternative disinfectants was carried out with stored water of the Rivers Rhine and Meuse. It was demonstrated that the increase of direct acting mutagens after treatment with chlo...

متن کامل

A methodology for the evaluation of disinfection technologies.

There are several concerns associated with the use of chlorine for potable water disinfection. These are the resistance of certain pathogens, the formation of toxic disinfection by-products and the adverse effects on aesthetic water quality. Owing to these concerns the water industry is continually reviewing alternative disinfection technologies. A methodology has been devised that will aid the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 69  شماره 

صفحات  -

تاریخ انتشار 1986