Effect of the TI/TE ratio on mean intratracheal pressure in high-frequency oscillatory ventilation.
نویسندگان
چکیده
In high-frequency oscillatory ventilation (HFOV), an adequate mean airway pressure is crucial for successful ventilation and optimal gas exchange, but air trapping cannot be detected by the usual measurement at the y piece. Intratracheal pressures produced by the high-frequency oscillators HFV-Infantstar (IS), Babylog 8000 (BL), and the SensorMedics 3100A (SM) [the latter with either 30% (SM30) or 50% (SM50) inspiratory time] were investigated in four anesthetized tracheotomized female piglets that were 1 day old and weighed 1.6-1.9 kg (mean 1.76 kg). The endotracheal tube was repeatedly clamped while the piglets were ventilated with an oscillation frequency of 10 Hz, and the airway pressure distal of the clamp was recorded as a measure of average intrapulmonary pressure during oscillation. Clamping resulted in a significant decrease of mean airway pressure when the piglets were ventilated with SM30 (-0.86 cmH2O), BL (-0.66 cmH2O), and IS (-0.71 cmH2O), but airway pressure increased by a mean of 0.76 cmH2O with SM50. Intratracheal pressure, when measured by a catheter pressure transducer at various oscillation frequencies, was lower than at the y piece by 0.4-0.9 cmH2O (SM30), 0.3-3 cmH2O (BL), and 1-4.7 cmH2O (IS) but was 0.4-0.7 cmH2O higher with SM50. We conclude that the inspiratory-to-expiratory time (TI/TE) ratio influences the intratracheal and intrapulmonary pressures in HFOV and may sustain a mean pressure gradient between the y piece and the trachea. A TI/TE ratio < 1:1 may be useful to avoid air trapping when HFOV is used.
منابع مشابه
تاثیر تهویه مصنوعی نوسانی با فرکانس بالا در نارسایی شدید تنفسی نوزادان
Despite improvement of mechanical ventilation devices for infants, lung injury still causes morbidity and mortality in many cases. To determine the effect of high frequency oscillatory ventilation (HFOV) in infants with severe respiratory failure, 10 neonates were evaluated prospectively. Mean gestational age of these patients was 35 weeks and alveolar-arterial oxygen gradient (A-aDo2) and the ...
متن کاملHigh-frequency oscillatory ventilation for adult respiratory distress syndrome--a pilot study.
OBJECTIVE To evaluate the safety and effectiveness of high-frequency oscillatory ventilation using a protocol designed to recruit and maintain optimal lung volume in patients with severe adult respiratory distress syndrome (ARDS). SETTING Surgical and medical intensive care units in a tertiary care, military teaching hospital. DESIGN A prospective, clinical study. PATIENTS Seventeen patie...
متن کاملCombining high-frequency oscillatory ventilation and recruitment maneuvers in adults with early acute respiratory distress syndrome: the Treatment with Oscillation and an Open Lung Strategy (TOOLS) Trial pilot study.
OBJECTIVE To determine the safety, feasibility, and lung-recruitment efficacy of an explicit ventilation protocol combining high-frequency oscillatory ventilation and recruitment maneuvers. DESIGN Prospective, multiple-center, single-intervention pilot study. SETTING Four university-affiliated intensive care units. PATIENTS Twenty-five patients with early acute respiratory distress syndro...
متن کاملSpecific compliance and gas exchange during high-frequency oscillatory ventilation.
OBJECTIVES To evaluate the use of specific compliance (static compliance/functional residual capacity) to adjust mean airway pressure, resulting in optimal gas exchange during high-frequency oscillatory ventilation in a surfactant-deficient newborn piglet. DESIGN Prospective controlled animal study. SETTING Laboratory. SUBJECTS Eight newborn piglets at 5 days of age. BACKGROUND High-fre...
متن کاملEffect of I/E ratio on mean alveolar pressure during high-frequency oscillatory ventilation.
This study investigated factors contributing to differences between mean alveolar pressure (PA) and mean pressure at the airway opening (Pao) during high-frequency oscillatory ventilation (HFOV). The effect of the inspiratory-to-expiratory time (I/E) ratio and amplitude of oscillation on the magnitude of - Pao (Pdiff) was examined by using the alveolar capsule technique in normal rabbit lungs (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 84 5 شماره
صفحات -
تاریخ انتشار 1998