GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence.
نویسندگان
چکیده
PURPOSE The most common γ-aminobutyric-acid (GABA) editing approach, MEGA-PRESS, uses J-editing to measure GABA distinct from larger overlapping metabolites, but suffers contamination from coedited macromolecules (MMs) comprising 40 to 60% of the observed signal. MEGA-SPECIAL is an alternative method with better MM suppression, but is not widely used primarily because of its relatively poor spatial localization. Our goal was to develop an improved MM-suppressed GABA editing sequence at 3 Tesla. METHODS We modified a single-voxel MEGA-SPECIAL sequence with an oscillating readout gradient for improved spatial localization, and used very selective 30-ms editing pulses for improved suppression of coedited MMs. RESULTS Simulation and in vivo experiments confirmed excellent MM suppression, insensitive to the range of B0 frequency drifts typically encountered in vivo. Both intersubject and intrasubject studies showed that MMs, when suppressed by the improved MEGA-SPECIAL method, contributed approximately 40% to the corresponding MEGA-PRESS measurements. From the intersubject study, the coefficient of variation for GABA+/Cre (MEGA-PRESS) was 11.2% versus 7% for GABA/Cre (improved MEGA-SPECIAL), demonstrating significantly reduced variance (P = 0.005), likely coming from coedited MMs. CONCLUSIONS This improved MEGA-SPECIAL sequence provides unbiased GABA measurements with reduced variance as compared with conventional MEGA-PRESS. This approach is also relatively insensitive to the range of B0 drifts typically observed in in vivo human studies. Magn Reson Med 79:41-47, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
منابع مشابه
GABA editing at 3T with Macromolecule Suppression: MEGA-SPECIAL
Introduction. One commonly used method for in-vivo magnetic resonance spectroscopy (MRS) detection of γ-aminobutyric acid (GABA) is the MEGA-PRESS technique [1], which enables direct observation of the GABA resonance at 3.02 ppm. Unfortunately, direct quantification of GABA using MEGA-PRESS is complicated by co-editing of macromolecule (MM) signals, which also resonate at 3.02 ppm [2]. Two meth...
متن کاملArtefact minimized spectral editing at 7T: quick and accurate in-vivo detection of GABA
Introduction: Spectral editing techniques are used in MRS to improve the detection of low concentrated metabolites like GABA [1], of which signals are overlapped with resonances of other highly concentrated compounds, such as Creatine and macromolecules. However, these methods rely on subtraction of two in vivo MR spectra and, therefore, are prone to artefacts. MRS at high field benefits from h...
متن کاملSimultaneous in vivo spectral editing and water suppression.
Water suppression is typically performed in vivo by exciting the longitudinal magnetization in combination with dephasing, or by using frequency-selective coherence generation. MEGA, a frequency-selective refocusing technique, can be placed into any pulse sequence element designed to generate a Hahn spin-echo or stimulated echo, to dephase transverse water coherences with minimal spectral disto...
متن کاملGABA Fitting for MEGA-PRESS Sequences with Different Selective Inversion Frequencies
Introduction GABA detection faces the problem of contamination from co-edited macromolecule signal at 3.0 ppm (MM30) when using the MEGA-PRESS technique [1]. Therefore, direct quantification of GABA by LCModel software [2] yields the sum of GABA and MM30. One of the proposed methods to eliminate MM30 is to alternate the editing pulse between 1.9 ppm and 1.5 ppm, the latter a position symmetric ...
متن کاملDirect in vivo measurement of human cerebral GABA concentration using MEGA-editing at 7 Tesla.
Spectral editing of the GABA spin system is hampered by coediting of macromolecule (MM) coherences. To reduce contamination arising from MMs in spectra edited for GABA, the highest field strength currently available for human experimentation (7 Tesla) and MEGA-based editing were used. Despite judicious choice of experimental parameters, MM contamination was found to arise from field drifts. Whe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 79 1 شماره
صفحات -
تاریخ انتشار 2018