Cone-beam computed tomography in hypofractionated stereotactic radiotherapy for brain metastases

نویسندگان

  • Gianluca Ingrosso
  • Roberto Miceli
  • Dahlia Fedele
  • Elisabetta Ponti
  • Michaela Benassi
  • Rosaria Barbarino
  • Luana Di Murro
  • Emilia Giudice
  • Federico Santarelli
  • Riccardo Santoni
چکیده

BACKGROUND To assess interfraction translational and rotational setup errors, in patients treated with image-guded hypofractionated stereotactic radiotherapy, immobilized by a thermoplastic mask and a bite-block and positioned using stereotactic coordinates. METHODS 37 patients with 47 brain metastases were treated with hypofractionated stererotactic radiotherapy. All patients were immobilized with a combination of a thermoplastic mask and a bite-block fixed to a stereotactic frame support. Daily cone-beam CT scans were acquired for every patient before the treatment session and were matched online with planning CT images, for 3D image registration. The mean value and standard deviation of all translational (X, Y, Z) and rotational errors (θx, θy, θz) were calculated for the matching results of bone matching algorithm. RESULTS A total of 194 CBCT scans were analyzed. Mean +/- standard deviation of translational errors (X, Y, Z) were respectively 0.5 +/- 1.6 mm (range -5.7 and 5.9 mm) in X; 0.4 +/- 2.7 mm (range -8.2 and 12.1 mm) in Y; 0.4 +/- 1.9 mm (range -7.0 and 14 mm) in Z; median and 90th percentile were respectively within 0.5 mm and 2.4 mm in X, 0.3 mm and 3.2 mm in Y, 0.3 mm and 2.2 mm in Z. Mean +/- standard deviation of rotational errors (θx, θy, θz) were respectively 0.0 degrees+/- 1.3 degrees (θx) (range -6.0 degrees and 3.1 degrees); -0.1 degrees +/- 1.1 degrees (θy) (range -3.0 degrees and 2.4 degrees); -0.6 degrees +/- 1.4 degrees (θz) (range -5.0 degrees and 3.3 degrees). Median and 90th percentile of rotational errors were respectively within 0.1 degrees and 1.4 degrees (θx), 0.0 degrees and 1.2 degrees (θy), 0.0 degrees and 0.9 degrees (θz). Mean +/- SD of 3D vector was 3.1 +/- 2.1 mm (range 0.3 and 14.9 mm); median and 90th percentile of 3D vector was within 2.7 mm and 5.1 mm. CONCLUSIONS Hypofractionated stereotactic radiotherapy have the significant limitation of uncertainty in interfraction repeatability of the patient setup; image-guided radiotherapy using cone-beam computed tomography improves the accuracy of the treatment delivery reducing set-up uncertainty, giving the possibility of 3-dimensional anatomic informations in the treatment position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Positional Accuracy of Treating Multiple Versus Single Vertebral Metastases With Stereotactic Body Radiotherapy

The aim of this study is to determine whether stereotactic body radiotherapy for multiple vertebral metastases treated with a single isocenter results in greater intrafraction errors than stereotactic body radiotherapy for single vertebral metastases and to determine whether the currently used spinal cord planning organ at risk volume and planning target volume margins are appropriate. Intrafra...

متن کامل

A retrospective review of SBRT for larger brain metastases or post-resection cavities: preliminary evidence from the Knight Cancer Institute

Objective Radiation for brain metastases is typically delivered by whole brain radiation (WBRT), stereotactic radiosurgery (SRS), or a combination thereof. There are patients with lesions that are not candidates for SRS owing to a maximum target diameter >3 cm, for which avoiding WBRT may provide a quality of life benefit. Here, we report our early experience with stereotactic hypofractionated ...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل

The Role Of Image Guided And Intensity Modulated Stereotactic Radiotherapy For Patients With Metastatic And Locally Advanced Cancers

Background Intensity-modulated stereotactic radiotherapy achieves improvements in the ability to produce conformal stereotactic dose distributions by modulation of the intensity of individually delivered beamlets of radiation. Image-guided intensity-modulated stereotactic radiotherapy has emerged as a new treatment option in the multidisciplinary management of metastatic and locally advanced ca...

متن کامل

Use of Helical TomoTherapy for the Focal Hypofractionated Treatment of Limited Brain Metastases in the Initial and Recurrent Setting

BACKGROUND Whole-brain radiation therapy (WBRT), stereotactic radiosurgery (SRS), or both are commonly employed in the treatment of limited brain metastases in the initial or recurrent setting. Hypofractionated partial volume irradiation is also employed, however, published experience using helical TomoTherapy (HT) for this purposes is limited. We reviewed our institutional experience to assess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012