Inflow Inversion Recovery MR Angiography of Renal Arteries at 3.0 T: A Feasibility Study

نویسندگان

  • H. Onishi
  • T. Kim
  • M. Hori
  • T. Tsuboyama
  • A. Nakamoto
  • H. Higashihara
  • M. Tatsumi
  • K. Tomoda
  • M. Uike
چکیده

Purpose Noncontrast MR angiography for the imaging of the renal vasculature at 1.5 T has been reported in several studies (1, 2). In recent years, 3.0-T MR systems are being used clinically because of the great advantage in signal-to-noise ratio. The aim of the present study was to evaluate the feasibility of noncontrast MR angiography of the renal arteries using an Inflow Inversion Recovery (IFIR) sequence in healthy volunteers at 3.0 T. Materials and Methods Ten healthy volunteers were enrolled in this study. MR examinations were performed with a 3.0-T system (Signa HDx 3.0 T; GE Healthcare, Milwaukee, WI) using an 8-channel torso phased array coil. For noncontrast MR angiography of the renal arteries, a respiratory-triggered IFIR sequence with the parallel imaging technique (ASSET) was used. Scan parameters were as follows; TR = 4.9 ms, TE = 2.5 ms, TI = 1200 ms, flip angle = 70°, band width = 125 kHz, FOV = 340 x 272 mm, matrix size = 320 x 192, slice thickness = 2.0 mm, slice interval = 1.0 mm, slice number = 58 x 2 (ZIP 2), acceleration factor = 2. Maximum intensity projection (MIP) images and volume rendering three-dimensional images of the renal arteries were generated from the acquired MR angiography image data on a workstation (Advantage Workstation 4.2; GE Healthcare). The image quality of MIP images, delineation of the renal arteries, the presence or albescence of anatomic variation, the degree of the signal suppression of the inferior vena cava were evaluated visually by one radiologist. Results In nine of 10 cases, MR angiography with excellent image quality was obtained and both sides of renal arteries were finely delineated including peripheral branches. In four of 10 cases, two left renal arteries were observed (Figure). In addition, in one of four, two right renal arteries were also observed. As for the signal suppression of the inferior vena cava, the signal was completely suppressed in six of 10 cases, but inferior vena cava was partially demonstrated in the remaining four cases. Discussion Some drawbacks associated with an ultlahigh-field can be expected at 3.0 T, such as susceptibility artifacts and increase of specific absorption rate (SAR). However, the fine image data were acquired without deterioration by the susceptibility artifacts. There was not interruption in scan due to the limitation of SAR. In conclusion, the renal arteries were finely delineated by means of noncontrast MR angiography using an IFIR sequence at 3.0 T. The results suggest that noncontrast MR angiography using an IFIR sequence at 3.0 T may apply to the preoperative evaluation of the renal arteries anatomy for the renal transplantation donors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-contrast MR Angiography

Figure 1. NC-MRA (inflow inversion recovery) shows normal arterial vasculature of the lower extremities. PA, popliteal artery; AT, anterior tibial arteries; PT, posterior tibial arteries; and PER, peroneal arteries. Techniques for performing non-contrast MR angiography (NC-MRA) have been available since the introduction of MR imaging. These techniques were largely displaced by contrast-enhanced...

متن کامل

Inhance (Inflow Inversion Recovery) Non-contrast Renal MRA: Comparison with 3D Gadolinium Enhanced MRA in Clinical Patients

Purpose: Contrast-enhanced MR Angiography (CE-MRA) is a widely accepted technique for evaluation of the renal arteries; however, recent concerns regarding the development of nephrogenic systemic fibrosis (NSF) after gadolinium contrast agent administration in patients with reduced renal function have emphasized the need for robust non-contrast MRA methods. One such technique is steady state fre...

متن کامل

Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries

BACKGROUND Cardiac and navigator-gated, inversion-prepared non-enhanced magnetic resonance angiography techniques can accurately depict the renal arteries without the need for contrast administration. However, the scan time and effectiveness of navigator-gated techniques depend on the subject respiratory pattern, which at times results in excessively prolonged scan times or suboptimal image qua...

متن کامل

Evaluation of the renal arteries: Comparison of two types of Non-contrast MRA and Dynamic contrast MRA

Introduction; Dynamic contrast MR angiography (C MRA) has made a major role for evaluation of cardiovascular diseases. For evaluation of patients with renal insufficiency or history with adverse reactions, MR contrast media cannot be used. Non-contrast (NC) MRAs with several techniques have been introduced. Currently, we used two types of MRA; FIESTA with flow preparation pulse (Flow-Prep) base...

متن کامل

Non-Contrast-Enhanced MRA of the Renal Arteries using Inflow-Enhanced, Inversion-Recovery bSSFP: Validation against DSA in a Porcine Model of Renal Artery Stenosis

T. A. Bley, C. J. Francois, M. L. Schiebler, O. Wieben, N. Takei, W. Sun, M. Miyoshi, J. H. Brittain, R. F. Busse, T. M. Grist, and S. B. Reeder Radiology, University of Wisconsin Madison, Madison, WI, United States, Radiology and Medical Physics, University of Wisconsin Madison, Madison, WI, United States, MR Applied Sciences Laboratory, GE Healthcare, Tokyo, Japan, MR Applied Sciences Laborat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009