Fluorescence imaging of ATP in neutrophils from patients with sepsis using organelle-localizable fluorescent chemosensors

نویسندگان

  • Koichiro Sueyoshi
  • Yuka Sumi
  • Yoshiaki Inoue
  • Yoko Kuroda
  • Kumiko Ishii
  • Hitoshi Nakayama
  • Kazuhisa Iwabuchi
  • Yasutaka Kurishita
  • Hajime Shigemitsu
  • Itaru Hamachi
  • Hiroshi Tanaka
چکیده

BACKGROUND The activation of polymorphonuclear neutrophils (PMNs) plays an important role in sepsis. Previously, we showed that ATP release and feedback via ATP receptors are essential for PMN activation; however, the dynamics remain poorly understood. Two new fluorescent chemosensors, PMAP-1 and MitoAP-1, were developed to detect ATP in the plasma membrane and mitochondria of living cells, respectively. In this study, we aimed to evaluate ATP localization using these chemosensors in PMNs of sepsis patients. METHODS Live PMNs isolated from 16 sepsis patients and healthy controls (HCs) were stained with these chemosensors and observed by confocal microscopy, and their mean fluorescence intensities (MFIs) were evaluated using flow cytometry. CD11b expression in PMNs was also evaluated. RESULTS The MFIs of PMAP-1 and MitoAP-1 and CD11b expression in PMNs from sepsis patients on days 0-1 were significantly higher than those of HCs. The MFI of PMAP-1 and CD11b expression on days 3-4 decreased significantly compared to those observed at days 0-1, whereas MitoAP-1 MFI was maintained at a high level. The PMAP-1 MFI was significantly positively correlated with CD11b expression, white blood cell counts, neutrophil counts, and C-reactive protein levels in patients. CONCLUSIONS The higher MFIs of PMAP-1 and MitoAP-1 in sepsis patients suggest a pivotal role of ATP for PMN activation. The temporal difference in ATP levels suggests that ATP plays different roles in the mitochondria and on the cell surface. These data should contribute to the understanding of the dynamics of ATP in PMNs and help to develop a novel therapy for sepsis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of mesoporous silica SBA-15 with different organic molecules to gain chemical sensors: a review

The recognition of the biologically and environmentally important ions is of great interest in the field of chemical sensors in recent years. The fluorescent sensors as a powerful optical analytical technique for the detection of low level of various analytes such as anions and metal cations have been progressively developed due to the simplicity, cost effective, and selectivity for monitoring ...

متن کامل

Aminonaphthalimide-based imidazolium podands for turn-on fluorescence sensing of nucleoside polyphosphates.

New aminonaphthalimide imidazolium podands, which worked as luminescence chemosensors for selectively sensing nucleoside polyphosphates through a "turn-on" manner, were prepared for fluorescent imaging of ADP and ATP in living cells.

متن کامل

Spectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging

Introduction Non-invasive Fluorescent Reflectance Imaging (FRI) is used for accessing physiological and molecular processes in biological media. The aim of this article is to separate the overlapping emission spectra of quantum dots within tissue-equivalent phantom using SVD, Jacobi SVD, and NMF methods in the FRI mode. Materials and Methods In this article, a tissue-like phantom and an optical...

متن کامل

Volume, Conductivity and Scatter parameters of Neutrophils in Neonatal Sepsis – Is it a Cost-Effective Tool?

Background: Early diagnosis of neonatal sepsis is quite challenging. I/T ratio (immature to mature neutrophil ratio) is a highly sensitive marker of sepsis but is time-consuming and subjective. Off late, volume conductivity and scatter (VCS) of neutrophils are among the newer parameters available for screening a septic neonate. This study aimed to determine the correlation between the I/T ratio...

متن کامل

Thiourea-based fluorescent chemosensors for aqueous metal ion detection and cellular imaging.

We describe three significant advances in the use of thioureas as reporting elements for metal-responsive fluorescent chemosensors. First, on the basis of the crystal structure of a chemosensor analogue, we provide a deeper understanding of the details of the thiourea coordination environment. Second, we describe a new generation of chemosensors with higher affinities for Zn(2+) and Cd(2+) than...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016