Novel index for invasively assessing the coronary microcirculation.

نویسندگان

  • William F Fearon
  • Leora B Balsam
  • H M Omar Farouque
  • Anthony D Caffarelli
  • Robert C Robbins
  • Peter J Fitzgerald
  • Paul G Yock
  • Alan C Yeung
چکیده

BACKGROUND A relatively simple, invasive method for quantitatively assessing the status of the coronary microcirculation independent of the epicardial artery is lacking. METHODS AND RESULTS By using a coronary pressure wire and modified software, it is possible to calculate the mean transit time of room-temperature saline injected down a coronary artery. The inverse of the hyperemic mean transit time has been shown to correlate with absolute flow. We hypothesize that distal coronary pressure divided by the inverse of the hyperemic mean transit time provides an index of microcirculatory resistance (IMR) that will correlate with true microcirculatory resistance (TMR), defined as the distal left anterior descending (LAD) pressure divided by hyperemic flow, measured with an external ultrasonic flow probe. A total of 61 measurements were made in 9 Yorkshire swine at baseline and after disruption of the coronary microcirculation, both with and without an epicardial LAD stenosis. The mean IMR (16.9+/-6.5 U to 25.9+/-14.4 U, P=0.002) and TMR (0.51+/-0.14 to 0.79+/-0.32 mm Hg x mL(-1) x min(-1), P=0.0001), as well as the % change in IMR (147+/-66%) and TMR (159+/-105%, P=NS versus IMR % change), increased significantly and to a similar degree after disruption of the microcirculation. These changes were independent of the status of the epicardial artery. There was a significant correlation between mean IMR and TMR values, as well as between the % change in IMR and % change in TMR. CONCLUSIONS Measuring IMR may provide a simple, quantitative, invasive assessment of the coronary microcirculation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Invasive assessment of the coronary microcirculation: superior reproducibility and less hemodynamic dependence of index of microcirculatory resistance compared with coronary flow reserve.

BACKGROUND A simple, reproducible invasive method for assessing the coronary microcirculation is lacking. A novel index of microcirculatory resistance (IMR) has been shown in animals to correlate with true microvascular resistance and, unlike coronary flow reserve (CFR), to be independent of the epicardial artery. We sought to compare the reproducibility and hemodynamic dependence of IMR with C...

متن کامل

Prognostic impact of coronary microcirculation abnormalities in systemic sclerosis: a prospective study to evaluate the role of non-invasive tests

INTRODUCTION Microcirculation dysfunction is a typical feature of systemic sclerosis (SSc) and represents the earliest abnormality of primary myocardial involvement. We assessed coronary microcirculation status by combining two functional tests in SSc patients and estimating its impact on disease outcome. METHODS Forty-one SSc patients, asymptomatic for coronary artery disease, were tested fo...

متن کامل

Comparison of coronary thermodilution and Doppler velocity for assessing coronary flow reserve.

BACKGROUND Thermodilution coronary flow reserve (CFRthermo) is a new technique for invasively measuring coronary flow reserve (CFR) with a coronary pressure wire and is based on the ability of the pressure transducer to also measure temperature changes. Whether CFRthermo correlates well enough with absolute flow-derived CFR (CFRflow) to replace Doppler wire-derived CFR (CFRDoppler) remains uncl...

متن کامل

Intracoronary Delivery of Human Mesenchymal/Stromal Stem Cells: Insights from Coronary Microcirculation Invasive Assessment in a Swine Model

BACKGROUND Mesenchymal stem/stromal cells have unique properties favorable to their use in clinical practice and have been studied for cardiac repair. However, these cells are larger than coronary microvessels and there is controversy about the risk of embolization and microinfarctions, which could jeopardize the safety and efficacy of intracoronary route for their delivery. The index of microc...

متن کامل

Assessment of coronary microcirculation in a swine animal model.

Coronary microvascular dysfunction has important prognostic implications. Several hemodynamic indexes, such as coronary flow reserve (CFR), microvascular resistance, and zero-flow pressure (P(zf)), were used to establish the most reliable index to assess coronary microcirculation. Fifteen swine were instrumented with a flow probe, and a pressure wire was advanced into the distal left anterior d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 107 25  شماره 

صفحات  -

تاریخ انتشار 2003