The National Eye Institute 25-Item Visual Function Questionnaire (NEI VFQ-25) – reference data from the German population-based Gutenberg Health Study (GHS)
نویسندگان
چکیده
BACKGROUND To estimate the burden of diseases, it is important to consider patient-reported outcomes including Quality of Life (QoL). The aim of this study is to provide population-based reference data for the National Eye Institute 25-Item Visual Function Questionnaire (NEI VFQ-25), stratified by sex and age. METHODS The Gutenberg Health Study (GHS) is a population-based, prospective, observational cohort study in Germany, including 15,010 participants aged between 35 and 74. The baseline examination was conducted between 2007 and 2012. To overcome known shortcomings of the NEI VFQ-25, we calculated the previously proposed visual functioning scale and the socio-emotional scale based on Rasch-transformed person-level data. We present mean values, standard deviations and percentiles for age decades stratified by sex. We used a linear regression model to assess the influence of age, sex, socioeconomic status, distance-corrected visual acuity (better-seeing eye) and the absolute difference in distance-corrected visual acuity of both eyes on vision-related QoL. RESULTS NEI VFQ-25 data are available from 12,231 participants (82%). Both the long-form visual functioning scale (LFVFS) and the long-form socio-emotional scale (LFSES) showed a clear age dependency, with an average LFVFS score of 92.8 for men and 90.5 for women in the youngest age group and 85.7 and 83.4 in the oldest age group, and a LFSES score of 98.3 for men and 98.1 in women in the youngest and 94.7 and 94.5 in the oldest decade. The largest difference was observed between the youngest age group (35-44 years) and the 45-54 years group. Men tended to have slightly higher scores than women. In the multivariable linear regression analysis, age (per 5 years -0.42), female sex (-1.57), worse distance-corrected visual acuity of the better eye (per 0.1 increase in logMAR -2.92) and the difference between both eyes (per 0.1 increase in logMAR -0.87) were associated with a reduced LFVFS score (all p < 0.001). For the LFSES score, we showed that the influence of sex was minor, and that age (per 5 years -0.22), visual acuity of the better eye (-1.65), and the difference between both eyes (-0.56) were associated with a lower score (all p < 0.001). CONCLUSIONS We report age- and sex-specific reference data from a large population-based study of mainly Caucasian ethnicity of two unidimensional scores based on Rasch-transformed NEI VFQ-25 data. Vision-related QoL is lower in older and in female individuals. Our results support the association of vision-related QoL not only with the distance-corrected visual acuity of the better eye but also with the difference in visual acuity between each eye. Our findings could be used as a reference for comparison in future studies addressing the influence of eye diseases on vision-related QoL.
منابع مشابه
Development of the 25-item National Eye Institute Visual Function Questionnaire.
OBJECTIVE To develop and test the psychometric properties of a 25-item version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). DESIGN Prospective observational cohort study of persons with 1 of 5 chronic eye diseases or low vision who were scheduled for nonurgent visits in ophthalmology practices and a reference sample of persons without eye disease. SETTING Eleven...
متن کاملVisual functioning and general health status in patients with uveitis.
OBJECTIVE To measure the visual functioning and quality of life in patients with uveitis. METHODS Consecutive adult patients with noninfectious uveitis were enrolled. The Medical Outcomes Study 36-Item Short Form (SF-36) and the National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25) were administered by a trained interviewer. Sociodemographic and clinical data were also collecte...
متن کاملPsychometric properties of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25), Japanese version
BACKGROUND The importance of evaluating the outcomes of health care from the standpoint of the patient is now widely recognized. The purpose of this study is to develop and test a Japanese version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). METHODS A Japanese version was developed with a previously standardized method. The questionnaire and optional items were co...
متن کاملDevelopment of a new Rasch-based scoring algorithm for the National Eye Institute Visual Functioning Questionnaire to improve its interpretability
BACKGROUND The NEI VFQ-25 has undergone psychometric evaluation in patients with varying ocular conditions and the general population. However, important limitations which may affect the interpretation of clinical trial results have been previously identified, such as concerns with reliability and validity. The purpose of this study was to evaluate the National Eye Institute Visual Functioning ...
متن کاملRemediating serious flaws in the National Eye Institute Visual Function Questionnaire.
PURPOSE To test the assumption that the National Eye Institute Visual Function Questionnaire (NEI VFQ) measures visual functioning, assess the validity of its subscales, and, if flawed, revise the questionnaire and derive a shortened version with sound psychometric properties. SETTING Flinders Medical Centre, Adelaide, Australia. METHODS Patients from the cataract surgery waiting list self-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2017