Blind identification of the aortic pressure waveform from multiple peripheral artery pressure waveforms.
نویسندگان
چکیده
We have developed a new technique to estimate the clinically relevant aortic pressure waveform from multiple, less invasively measured peripheral artery pressure waveforms. The technique is based on multichannel blind system identification in which two or more measured outputs (peripheral artery pressure waveforms) of a single-input, multi-output system (arterial tree) are mathematically analyzed so as to reconstruct the common unobserved input (aortic pressure waveform) to within an arbitrary scale factor. The technique then invokes Poiseuille's law to calibrate the reconstructed waveform to absolute pressure. Consequently, in contrast to previous related efforts, the technique does not utilize a generalized transfer function or any training data and is therefore entirely patient and time specific. To demonstrate proof of concept, we have evaluated the technique with respect to four swine in which peripheral artery pressure waveforms from the femoral and radial arteries and a reference aortic pressure waveform from the descending thoracic aorta were simultaneously measured during diverse hemodynamic interventions. We report that the technique reliably estimated the entire aortic pressure waveform with an overall root mean squared error (RMSE) of 4.6 mmHg. For comparison, the average overall RMSE between the peripheral artery pressure and reference aortic pressure waveforms was 8.6 mmHg. Thus the technique reduced the RMSE by 47%. As a result, the technique also provided similar improvements in the estimation of systolic pressure, pulse pressure, and the ejection interval. With further successful testing, the technique may ultimately be employed for more precise monitoring and titration of therapy in, for example, critically ill and hypertension patients.
منابع مشابه
An adaptive transfer function for deriving the aortic pressure waveform from a peripheral artery pressure waveform.
We developed a new technique to mathematically transform a peripheral artery pressure (PAP) waveform distorted by wave reflections into the physiologically more relevant aortic pressure (AP) waveform. First, a transfer function relating PAP to AP is defined in terms of the unknown parameters of a parallel tube model of pressure and flow in the arterial tree. The parameters are then estimated fr...
متن کاملEstimation of pressure pulse amplification between aorta and brachial artery using stepwise multiple regression models.
The pressure pulse is amplified between the aorta and peripheral sites. This study compares two methods to estimate pressure pulse amplification (PPA) between the aorta and the brachial artery. Method 1: PPA was determined from a multi-parameter linear regression of subject parameters (gender, age, height, weight, heart rate (HR), brachial systolic pressure (BSP), diastolic pressure (BDP), mean...
متن کاملUse of the Kalman Filter for Aortic Pressure Waveform Noise Reduction
Clinical applications that require extraction and interpretation of physiological signals or waveforms are susceptible to corruption by noise or artifacts. Real-time hemodynamic monitoring systems are important for clinicians to assess the hemodynamic stability of surgical or intensive care patients by interpreting hemodynamic parameters generated by an analysis of aortic blood pressure (ABP) w...
متن کاملCan a clinically useful aortic pressure wave be derived from a radial pressure wave?
BACKGROUND The information contained in arterial pressure waveforms is probably underused by most clinicians who manage critically ill patients. It is not generally known that an aortic pressure wave can be synthesized by applying a generalized transfer function to the radial arterial pressure wave. We validated a commercially available system, SphygmoCo (PWV Medical, Sydney). METHODS Ascendi...
متن کاملValidation of the transfer function technique for generating central from peripheral upper limb pressure waveform.
Central aortic pressure waveforms can be calculated from the radial artery pressure waveform using a generalized transfer function to correct for pressure wave distortion in the upper limb. Although validated to standards conventionally applied, reservations are still expressed on use of this process, because of the relatively small number of patients from whom appropriate invasive data were ob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 292 5 شماره
صفحات -
تاریخ انتشار 2007