Relation between denaturation time measured by optical coherence reflectometry and thermal lesion depth during radiofrequency cardiac ablation: Feasibility numerical study.

نویسندگان

  • Ana González-Suárez
  • David Herranz
  • Enrique Berjano
  • Jose L Rubio-Guivernau
  • Eduardo Margallo-Balbás
چکیده

BACKGROUND/OBJECTIVE Radiofrequency (RF) catheter ablation is a minimally invasive medical procedure used to thermally destroy the focus of cardiac arrhythmias. Novel optical techniques are now being integrated into RF catheters in order to detect the changes in tissue properties. Loss of birefringence due to fiber denaturation at around 70°C is related to changes in accumulated phase retardation and can be measured by polarization-sensitive optical coherence reflectometry (PS-OCR). Since irreversible thermal lesions are produced when the tissue reaches 50°C, our goal was to seek the mathematical relationship between both isotherms. MATERIALS AND METHODS A two-dimensional model based on a coupled electric-thermal problem was built and solved using the finite element method. The model consisted of cardiac tissue, blood, and a non-irrigated electrode with a sensor embedded in its tip to maintain a specific target electrode temperature. Computer simulations were conducted by varying the tissue characteristics. Lesion depth was estimated by the 50°C isotherm, while the denaturation time (TD) was taken as the time at which the 70°C isotherm reached a depth of 0.75 mm (which corresponds to the optical depth reached by PS-OCR technology). RESULTS A strong correlation (R2  > 0.83) was found between TD and lesion depth and an even stronger correlation (R2  > 0.96) was found between TD and the time required to achieve a specific lesion depth. For instance, the ablation time required to ensure a minimum lesion depth of 3 mm was 1.33 × TD + 3.93 × seconds. CONCLUSIONS The computer results confirmed the strong relationship between denaturation time and lesion depth and suggest that measuring denaturation time by PS-OCR could provide information on the ablation time required to reach a specific lesion depth. Lasers Surg. Med. 50:222-229, 2018. © 2017 Wiley Periodicals, Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.

BACKGROUND The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. METHODS AND RESULTS Fifteen radiofrequency lesions of 6 to 240 seconds in dur...

متن کامل

Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo

BACKGROUND Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. METHODS MR t...

متن کامل

In vitro characterization of cardiac radiofrequency ablation lesions using optical coherence tomography.

Currently, cardiac radiofrequency ablation (RFA) is guided by indirect signals. We demonstrate optical coherence tomography (OCT) characterization of RFA lesions within swine ventricular wedges. Untreated tissue exhibited a consistent birefringence artifact within OCT images due to the organized myocardium, which was not present in treated tissue. Birefringence artifacts were detected by filter...

متن کامل

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

Comparison of Tissue Architectural Changes between Radiofrequency Ablation and Cryospray Ablation in Barrett's Esophagus Using Endoscopic Three-Dimensional Optical Coherence Tomography

Two main nonsurgical endoscopic approaches for ablating dysplastic and early cancer lesions in the esophagus have gained popularity, namely, radiofrequency ablation (RFA) and cryospray ablation (CSA). We report a uniquely suited endoscopic and near-microscopic imaging modality, three-dimensional (3D) optical coherence tomography (OCT), to assess and compare the esophagus immediately after RFA a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 2018