Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

نویسندگان

  • Lutz Weise
  • Olaf Suess
  • Thomas Picht
  • Theodoros Kombos
چکیده

OBJECTIVE Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system. METHODS Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision(®), Stryker). The accuracy of placement was assessed postoperatively by CT scan, and the patients were followed-up clinically for a mean of 16 months. RESULTS The total medio-caudal pedicle wall perforation rate was 9.2% (30/326). In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more) was 3.37% (11/326). Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period. CONCLUSION We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report.

Thirteen patients with fractures and/or dislocations of the middle and lower cervical spine were treated by transpedicular screw fixation using the Steffee variable screw placement system. Postoperative immobilization was either not used or simplified to short-term use of a soft neck collar. Recovery of nerve function and correction of kyphotic and/or translational deformities were satisfactory...

متن کامل

Improving the trajectory of transpedicular transdiscal lumbar screw fixation with a computer-assisted 3D-printed custom drill guide

Transpedicular transdiscal screw fixation is an alternative technique used in lumbar spine fixation; however, it requires an accurate screw trajectory. The aim of this study is to design a novel 3D-printed custom drill guide and investigate its accuracy to guide the trajectory of transpedicular transdiscal (TPTD) lumbar screw fixation. Dicom images of thirty lumbar functional segment units (FSU...

متن کامل

A Novel Blasted and Grooved Low Profile Pedicle Screw Able to Resist High Compression Bending Loads

OBJECTIVE Polyaxial pedicle screws are a safe, useful adjunct to transpedicular fixation. However, the large screw head size can cause soft tissue irritation, high rod positioning, and facet joint injury. However, the mechanical resistance provided by small and low profile pedicle screws is very limited. We therefore developed a novel, low profile pedicle screw using grooving and blasting treat...

متن کامل

Percutaneous Transpedicular Fixation: Technical tips and Pitfalls of Sextant and Pathfinder Systems.

STUDY DESIGN The efficacy of the operative techniques, possible benefits as well as pitfalls and limitations of the techniques are discussed. Potential drawbacks are also detected. PURPOSE This study aims to report indications, techniques, and our experience with the use of the Sextant and PathFinder percutaneous transpedicular screw fixation systems. OVERVIEW OF LITERATURE Percutaneous ped...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2008