Interventional radiological retrieval of embolized vascular access device fragments.

نویسندگان

  • Baran Önal
  • Bilgen Coşkun
  • Ramazan Karabulut
  • Erhan T Ilgıt
  • Zafer Türkyilmaz
  • Kaan Sönmez
چکیده

PURPOSE Vascular access device fragment embolization is a relatively rare but potentially serious complication. The purpose of this study was to report our experience with endovascular retrieval of embolized vascular access device fragments by interventional radiological means. MATERIALS AND METHODS Ten patients with a vascular access device fragment embolism were treated between 2004 and 2010. Attempted retrieval from the vascular bed was performed for five port catheter fragments, two temporary catheter fragments and three guide wires. The demographic data, underlying disease of the patients, type of inserted catheters, interval between implantation and discovery of embolism, interval between discovery of embolization and retrieval and localization and length of the embolized fragments were identified from the patient charts. RESULTS In nine of the ten patients (90%), radiologic intervention retrieval of the embolized vascular access device fragments was successful. The reasons for intravascular fragment embolism consisted of rupture at the connection site of the chamber or the external hub and the intravascular catheter (n=4), pinchoff syndrome (n=3), operator inexperience (n=3). Embolized catheter fragments or guide wires were retrieved under fluoroscopy by a gooseneck snare. The postprocedural course was uneventful. CONCLUSION The radiological retrieval of embolized vascular access device fragments is the preferred method, and it has a high success rate. Considering the potential for devastating complications, patients should be referred to interventional radiology, and the embolized catheters should be retrieved using interventional endovascular techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous retrieval of centrally embolized fragments of central venous access devices or knotted Swan-Ganz catheters. Clinical report of 14 retrievals with detailed angiographic analysis and review of procedural aspects

INTRODUCTION Totally implantable venous access systems (TIVAS), Swan-Ganz (SG) and central venous catheters (CVC) allow easy and repetitive entry to the central cardiovascular system. Fragments of them may be released inadvertently into the cardiovascular system during their insertion or as a result of mechanical complications encountered during long-term utilization. AIM To present results o...

متن کامل

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

Tough, but not impossible – Retrieval of large atrial septal occluder devices embolized to left atrium

Atrial septal defect (ASD) is a congenital heart defect that is being increasingly treated using percutaneous interventions. However, these techniques are not devoid of complications. One such complication is device embolization. Removal of such closure device poses tremendous risk and consequent complications both by percutaneous retrieval and surgical removal. Herein, we present two cases of ...

متن کامل

Initial experience with Angioseal™: Safety and efficacy of the endovascular closure device

BACKGROUND Vascular access site management is crucial to safe, efficient, and comfortable diagnostic or interventional percutaneous procedures. The Angioseal™ vascular closure device has been shown to be safe and effective in reducing the time to hemostasis following angiographic or interventional procedures. Relatively few studies have been conducted in the UK to assess the safety and efficacy...

متن کامل

Successful Image-Guided Retrieval of an Embolized Fragment of a Fractured Haemodialysis Catheter Tip from the Pulmonary Artery

BACKGROUND Cuffed, double-lumen, tunneled haemodialysis catheters are a common means of vascular access in paediatric haemodialysis, particularly in infants. Haemodialysis catheter fracture with distal embolization is a rare complication. CASE REPORT A 2-year-old boy was receiving chronic haemodialysis via a right internal jugular cuffed, double-lumen, tunneled haemodialysis catheter, inserte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2012