Self-ligating vs conventional twin brackets during en-masse space closure with sliding mechanics.

نویسنده

  • Peter G Miles
چکیده

INTRODUCTION The aim of this study was to compare the rate of en-masse space closure with sliding mechanics between passive self-ligating SmartClip brackets (3M Unitek, Monrovia, Calif) and conventional twin brackets ligated with stainless steel ligatures. METHODS Nineteen patients including 20 arches participated in this prospective trial with 0.018-in slot brackets. All patients had first premolar extractions in at least 1 arch, with the second premolar and the first molar distal to the extraction site bonded with SmartClip brackets on 1 side and conventional twin brackets on the other. The sides were alternated with each consecutive patient. Space closure was achieved on 0.016 x 0.022-in stainless steel wires with nickel-titanium coil springs activated 6 to 9 mm. The patients were recalled every 5 weeks until 1 side had closed. The distances from the mesial aspect of the canine bracket to the distal aspect of the first molar bracket were recorded before and after space closure, and an average rate of space closure per month was calculated. RESULTS Thirteen patients completed the trial (14 arches); the median rates of tooth movement for the SmartClip bracket side (1.1 mm per month) and the conventional twin bracket side (1.2 mm per month) were not significantly different (P = .86). CONCLUSIONS There was no significant difference in the rate of en-masse space closure between passive SmartClip brackets and conventional twin brackets tied with stainless steel ligatures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maxillary canine retraction with self-ligating and conventional brackets.

OBJECTIVE To measure space closure during the retraction of upper permanent canines with self-ligating and conventional brackets. MATERIALS AND METHODS Fifteen patients who required maxillary canine retraction into first premolar extraction sites as part of their orthodontic treatment completed this study. In a random split-mouth design, the retraction of upper canines was performed using an ...

متن کامل

Archwire depth is a significant parameter in the frictional resistance of active and interactive, but not passive, self-ligating brackets.

OBJECTIVE To elucidate some of the parameters determining the frictional behavior of passive, active, and interactive self-ligating brackets during sliding mechanics. MATERIALS AND METHODS A custom jig mimicking the three-dimensional tooth movements that occur during sliding mechanics and an Instron testing machine were used to determine the resistance to sliding of six different self-ligatin...

متن کامل

Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

OBJECTIVE To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. METHODS Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archw...

متن کامل

Opening and closure forces of sliding mechanisms of different self-ligating brackets

UNLABELLED Self-ligating brackets engage the wire by means of a slide mechanism. Forces that have to be applied to open and close the sliding mechanism of brackets are still unknown. OBJECTIVE The aim of this study was to measure and compare the opening and closure forces of different self-ligating brackets. MATERIAL AND METHODS Three different stainless steel self-ligating brackets (Carrie...

متن کامل

Forces released during sliding mechanics with passive self-ligating brackets or nonconventional elastomeric ligatures.

INTRODUCTION The aim of this study was to evaluate the frictional forces generated by 4 types of passive stainless steel self-ligating brackets (SLBs) and by nonconventional elastomeric ligatures (NCEL) and conventional elastomeric ligatures (CEL) during sliding mechanics. METHODS An experimental model consisting of 5 aligned stainless steel 0.022-in brackets was used to assess frictional for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics

دوره 132 2  شماره 

صفحات  -

تاریخ انتشار 2007