Transoesophageal echocardiography of aortic atherosclerosis: the additive value of three-dimensional over two-dimensional imaging.
نویسندگان
چکیده
AIMS Complex aortic atherosclerotic plaques (AAPs) carry a significant risk of embolism. Currently, two-dimensional (2D) transoesophageal echocardiography (TOE) is the principal diagnostic tool of AAPs. However, we hypothesized that the data obtained from three-dimensional (3D) imaging may improve AAPs' spatial assessment. METHODS AND RESULTS The study included 67 patients (aged 70 ± 15 years, 35 men), who had routine TEE studies. The thoracic aorta was studied from arch to distal descending aorta, using the x-plane mode (simultaneous short- and long-axis views). If focal intimal thickening (suggestive of AAP) was detected, the 3D zoom algorithm was exercised on the specific site with further post-processing on a Q-lab workstation to measure its thickness in the X, Y, and Z dimensions. The AAP contour was defined qualitatively as regular or irregular in each mode. A total of 100 AAPs were investigated. The AAP thickness estimation was significantly greater in the 3D mode than in the 2D mode (0.51 ± 0.33 vs. 0.28 ± 0.20 cm, P < 0.001). The rate of complex AAPs (defined by AAP thickness of ≥4 mm) was two-fold higher with 3D imaging than with 2D imaging (27% with 2D imaging alone vs. 53% with the addition of 3D imaging). The rate of irregular AAPs increased from 29 to 65% when assessed with 3D imaging compared with 2D imaging. CONCLUSION This study has shown a significant difference in the estimation of AAPs between 2D and 3D TEE. The significant shift to a more complex AAPs profile may suggest that 3D imaging is preferable for the assessment of aortic atherosclerosis burden.
منابع مشابه
Three Different Imaging Modalities of a Patient with the Aortic Coarctation
The patient was a 19 year-old woman with the diagnosis of resistant hypertension, although she was under treatment of three classes of anti-hypertensive drugs (beta blocker, angiotensin receptor blocker, diuretic) for more than one year. In physical examination there was only a significant difference between the systolic blood pressure of upper and lower extremities (200 vs. 120 mmHg), without ...
متن کاملThe efficacy of real-time three-dimensional transoesophageal echocardiography in detecting unicuspid aortic valve.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/ehjci/jes120 Online publish-ahead-of-pr...
متن کاملTranscatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.
AIMS To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter c...
متن کاملReal-time three-dimensional transoesophageal echocardiographic imaging of an aorto-left atrial fistula.
A 21-year-old man with Marfan syndrome with aortic and mitral mechanical prosthetic valve presented with a type-3 aortic dissection. A successful endovascular aortic repair with graft stent was performed. On the fifth day of admission, he was uneventfully discharged. But ten days later, he represented with dyspnoea, high fever (39.2°C) and chills. He had a 4/6 diastolic murmur at aortic point i...
متن کاملUsefulness of real-time three-dimensional transoesophageal echocardiography in the assessment of chronic aortic dissection.
AIMS To assess the usefulness of three-dimensional transoesophageal echocardiography (3D-TOE) vs. two-dimensional (2D)-TOE in the evaluation of morphological and dynamic findings of aortic dissection, and compare the results with those obtained by multi-slice computed tomography (CT). METHODS AND RESULTS Twenty-six patients (21 men and 5 women, median age: 67 years, range: 28-74 years) diagno...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 16 4 شماره
صفحات -
تاریخ انتشار 2015